Evidence map›Paper›PMID 33998654›Full record

ArticleJournal of radiation research2021

Technical Note: validation of a material assignment method for a retrospective study of carbon-ion radiotherapy using Monte Carlo simulation.

Weishan Chang, Yusuke Koba, Takuya Furuta, Shunsuke Yonai, Shintaro Hashimoto, Shinnosuke Matsumoto, Tatsuhiko Sato

Abstract readValidation Study
In one paragraph

Article in Journal of radiation research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Weishan ChangCenter for Radiation Protection Knowledge, National Institute of Radiological Sciences, QST, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555, Japan.
Yusuke KobaCenter for Radiation Protection Knowledge, National Institute of Radiological Sciences, QST, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555, Japan.
Takuya FurutaNuclear Science and Engineering Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Ibaraki 319-1195, Japan.
Shunsuke YonaiDepartment of Accelerator and Medical Physics, National Institute of Radiological Sciences, QST, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555, Japan.
Shintaro HashimotoNuclear Science and Engineering Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Ibaraki 319-1195, Japan.
Shinnosuke MatsumotoDepartment of Accelerator and Medical Physics, National Institute of Radiological Sciences, QST, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555, Japan.
Tatsuhiko SatoDepartment of Accelerator and Medical Physics, National Institute of Radiological Sciences, QST, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We propose a two-step method to converse human tissue materials from patient computed tomography (CT) images, which is required in dose reconstructions for a retrospective study of carbon-ion radiotherapy (CIRT) using Monte Carlo (MC) simulation. The first step was to assign the standard tissues of the International Commission on Radiological Protection reference phantoms according to the CT-number. The second step was to determine the mass density of each material based on the relationship between CT-number and stopping power ratio (Hounsfield unit [HU]-SPR) registered in treatment planning system (TPS). Direct implementation of the well-calibrated HU-SPR curve allows the reproduction of previous clinical treatments recorded in TPS without uncertainty due to a mismatch of the CT scanner or scanning conditions, whereas MC simulation with realistic human tissue materials can fulfill the out-of-field dose, which was missing in the record. To validate our proposed method, depth-dose distributions in the homogenous and heterogeneous phantoms irradiated by a 400 MeV/u carbon beam with an 8 cm spread-out Bragg peak (SOBP) were computed by the MC simulation in combination with the proposed methods and compared with those of TPS. Good agreement of the depth-dose distributions between the TPS and MC simulation (within a 1% discrepancy in range) was obtained for different materials. In contrast, fluence distributions of secondary particles revealed the necessity of MC simulation using realistic human tissue. The proposed material assignment method will be used for a retrospective study using previous clinical data of CIRT at the National Institute of Radiological Sciences (NIRS).

Indexed as

Heavy Ion RadiotherapyPhantoms, ImagingAdipose TissueAirAlgorithmsBone and BonesComputer SimulationHumansLungMonte Carlo MethodMuscle, SkeletalRetrospective StudiesToothcarbon-ion radiotherapy (CIRT)dose reconstructionmaterial assignment methodMonte Carlo (MC) simulation

Identifiers

PMID33998654
PMCPMC8438268

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.