Evidence map›Paper›PMID 33997323›Full record

ArticleTechnical innovations & patient support in radiation oncology2021

Evaluation of the XVI dual registration tool for image-guided radiotherapy in prostate cancer.

Filipa Sousa, Younes Jourani, Robbe Van den Begin, François-Xavier Otte, Sara Ridai, Maxime Desle, Angela Ferreira, Radia Ahmimed, Moniek C M van Klink-de Goeij, Dirk Van Gestel

Open access · goldAbstract read
In one paragraph

Article in Technical innovations & patient support in radiation oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Filipa SousaRadiation Oncology Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
Younes JouraniMedical Physics Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
Robbe Van den BeginRadiation Oncology Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
François-Xavier OtteRadiation Oncology Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
Sara RidaiRadiation Oncology Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
Maxime DesleRadiation Oncology Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
Angela FerreiraRadiation Oncology Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
Radia AhmimedRadiation Oncology Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
Moniek C M van Klink-de GoeijInholland University of Applied Sciences, School of Health, Haarlem, The Netherlands.
Dirk Van GestelRadiation Oncology Department, Institut Jules Bordet, Université Libre de Bruxelles, Brussels, Belgium.
Université Libre de Bruxelles · BEInholland University of Applied Sciences · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the reliability and the required time for two cone-beam CT (CBCT) registration methods for prostate irradiation (PI) and prostate bed irradiation (PBI). MATERIAL AND

methodsTwo-hundred treatment fractions (in 10 PI and 10 PBI patients) were reanalyzed, using two CBCT registration methods: (1) a combination of an automated chamfer matching (CM) with manual matching (MM), and (2) the automated XVI dual registration tool (DRT). Bland-Altman 95% Limits of Agreement (LoA) were used to assess agreement with manual registration by Radiation Oncologists.

resultsAll 95% LoA for CM + MM were ≤ 0.33 cm. For DRT, several 95% LoA were notably larger than the predefined clinical threshold of 0.3 cm: -0.47 to +0.25 cm (PI) and -0.36 to +0.23 cm (PBI) for the superior-inferior direction and -0.52 to +0.24 cm (PI) and -0.38 to +0.31 cm (PBI) for the anterior-posterior direction.For PI, the average time required was 33 s with CM + MM versus only 18 s with DRT (

conclusionFor PI, DRT was significantly faster than CM + MM, but the accuracy is insufficient to use without manual verification. Therefore, manual verification is still warranted, but could offset the time benefit. For PBI, the CM + MM method was faster and more accurate.

Identifiers

PMID33997323
PMCPMC8093993
OpenAlexW3155695118

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.