Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging.

Sandun Jayarathna, Md Foiez Ahmed, Liam O'Ryan, Hem Moktan, Yonggang Cui, Sang Hyun Cho

Abstract read
In one paragraph

Article in IEEE access : practical innovations, open solutions, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sandun JayarathnaDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
Md Foiez AhmedDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
Liam O'RyanQuantum Detectors Ltd., Oxford OX11 0QX, U.K.
Hem MoktanDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
Yonggang CuiBrookhaven National Laboratory, Upton, NY 11973, USA.
Sang Hyun ChoDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.ORCID 0000-0002-6357-5042

Funding

Towards in vivo imaging with benchtop x-ray fluorescence computed tomographyR01EB020658 · NIBIB · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI CHO, SANG HYUN · 2016 to 2019
$3.0M
NIBIB NIH HHS R01 EB020658
6 · The paper itself

Abstract

Pixelated semi-conductor detectors providing high energy resolution enable parallel acquisition of x-ray fluorescence (XRF) signals, potentially leading to performance enhancement of benchtop XRF imaging or computed tomography (XFCT) systems utilizing ordinary polychromatic x-ray sources. However, little is currently known about the characteristics of such detectors under typical operating conditions of benchtop XRF imaging/XFCT. In this work, a commercially available pixelated cadmium telluride (CdTe) detector system, HEXITEC (High Energy X-ray Imaging Technology), was characterized to address this issue. Specifically, HEXITEC was deployed into our benchtop cone-beam XFCT system, and used to detect gold K

Indexed as

benchtop x-ray fluorescence computed tomographygold nanoparticlesHEXITECPixelated CdTe detectorx-ray fluorescence

Identifiers

PMID33996343
PMCPMC8117933

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.