Evidence map›Paper›PMID 33996201›Full record

ArticleBiomedical optics express2021

Axial accuracy and signal enhancement in acoustic-resolution photoacoustic microscopy by laser jitter effect correction and pulse energy compensation.

Amir Asadollahi, Hamid Latifi, Manojit Pramanik, Hamed Qazvini, Ali Rezaei, Hamed Nikbakht, Abolfazl Abedi

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Photoacoustic imaging aided with deep learning: a review.Biomedical engineering letters · 2022
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 3 countries.

Amir AsadollahiLaser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran.
Hamid LatifiLaser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran.ORCID https://orcid.org/0000-0002-0234-8612
Manojit PramanikSchool of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore.ORCID https://orcid.org/0000-0003-2865-5714
Hamed QazviniLaser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran.
Ali RezaeiLaser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran.
Hamed NikbakhtLaser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran.ORCID https://orcid.org/0000-0001-8158-5685
Abolfazl AbediDepartment of Electrical Engineering, Shahid Beheshti University, Tehran, Iran.
Shahid Beheshti University · IRNanyang Technological University · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In recent years, photoacoustic imaging has found vast applications in biomedical imaging. Photoacoustic imaging has high optical contrast and high ultrasound resolution allowing deep tissue non-invasive imaging beyond the optical diffusion limit. Q-switched lasers are extensively used in photoacoustic imaging due to the availability of high energy and short laser pulses, which are essential for high-resolution photoacoustic imaging. In most cases, this type of light source suffers from pulse peak-power energy variations and timing jitter noise, resulting in uncertainty in the output power and arrival time of the laser pulses. These problems cause intensity degradation and temporal displacement of generated photoacoustic signals which in turn deteriorate the quality of the acquired photoacoustic images. In this study, we used a high-speed data acquisition system in combination with a fast photodetector and a software-based approach to capture laser pulses precisely in order to reduce the effect of timing jitter and normalization of the photoacoustic signals based on pulse peak-powers simultaneously. In the experiments, maximum axial accuracy enhancement of 14 µm was achieved in maximum-amplitude projected images on XZ and YZ planes with ±13.5 ns laser timing jitter. Furthermore, photoacoustic signal enhancement of 77% was obtained for 75% laser pulses peak-power stability.

Identifiers

PMID33996201
PMCPMC8086458
OpenAlexW3132656574

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.