Evidence map›Paper›PMID 33994451›Full record

ArticleNeurologia medico-chirurgica2021

Streak Metal Artifact Reduction Technique in Cone Beam Computed Tomography Images after Endovascular Neurosurgery.

Takafumi Otsuka, Masahiro Nishihori, Takashi Izumi, Takeshi Uemura, Takashi Sakai, Mizuki Nakano, Naoki Kato, Fumiaki Kanamori, Tetsuya Tsukada, Kenji Uda and 3 more

Open access · goldAbstract read
In one paragraph

Article in Neurologia medico-chirurgica, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.4field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 2 institutions in 1 country.

Takafumi OtsukaDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Masahiro NishihoriDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Takashi IzumiDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Takeshi UemuraRadiological Technology, Department of Medical Technique, Nagoya University Hospital.
Takashi SakaiRadiological Technology, Department of Medical Technique, Nagoya University Hospital.
Mizuki NakanoDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Naoki KatoDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Fumiaki KanamoriDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Tetsuya TsukadaDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Kenji UdaDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Kinya YokoyamaDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Yoshio ArakiDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Ryuta SaitoDepartment of Neurosurgery, Nagoya University Graduate School of Medicine.
Nagoya University · JPNagoya University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cone beam computed tomography (CBCT) images are degraded by artifacts due to endovascular implants. We evaluated the use of streak metal artifact reduction technique (SMART) in non-contrast CBCT images after endovascular neurosurgery obtained from 148 patients (125 with aneurysm and 23 with dural arteriovenous fistula [dAVF]). Three neurosurgeons evaluated the cistern and brain surface visibility in CBCT images with and without SMART correction based on a 4-point scale (1, excellent; 2, good; 3, limited; and 4, insufficient). Significant improvement in visibility was achieved when the median scores improved from 4 or 3 to 2 or 1 or from 2 to 1. Metal artifact reduction in adjacent slices without metal and new artifacts after SMART correction was also examined. A significant improvement was achieved regarding the visibility of the cistern in 90 (60.8%) images and of the brain surface in 108 (73.0%) images. Metal size (cistern: odds ratio [OR], 0.91 per 1 mm increase; 95% confidence interval [CI], 0.83-0.99), irregular metal shape (cistern: OR, 0.18; 95% CI, 0.05-0.60 and brain surface: OR, 0.15; 95% CI, 0.05-0.45), and infratentorial lesions (cistern: OR, 0.37; 95% CI, 0.14-0.96 and brain surface: OR, 0.30; 95% CI, 0.11-0.80) were negatively correlated with improved visibility. Metal artifact reduction in adjacent slices without metal was obtained in 25.6% and 34.8% of images with aneurysm and dAVF, respectively. New artifacts after SMART correction were found in 4.8% and 13.0% of images with aneurysm and dAVF, respectively. SMART is especially effective for supratentorial small aneurysms.

Indexed as

ArtifactsNeurosurgeryAlgorithmsCone-Beam Computed TomographyHumansMetalsMetalsaneurysmdural arteriovenous fistulaendovascular neurosurgerynon-contrast cone beam computed tomographystreak metal artifact reduction technique

Identifiers

PMID33994451
PMCPMC8365234
OpenAlexW3162183489

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked