ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2021
Comparison of degenerative lumbar scoliosis correction and risk for mechanical failure using posterior 2-rod instrumentation versus 4-rod instrumentation and interbody fusion.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Spinopelvic Realignment and Clinical Outcomes After Surgical Management of Adult Degenerative Lumbar Deformity: A Multicenter Retrospective Cohort Study.Journal of clinical medicine · 2026Article
- Development and validation of machine learning models for distal instrumentation-related problems in patients with degenerative lumbar scoliosis based on preoperative CT and MRI.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025Article
- Influence of implant density on mechanical complications in adult spinal deformity surgery.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2024Article
- Multiple-Rod Constructs in Adult Spinal Deformity Surgery: A Systematic Review and Meta-Analysis.Asian spine journal · 2023Article
- The role of lumbosacral paraspinal muscle degeneration and low vertebral bone mineral density on distal instrumentation-related problems following long-instrumented spinal fusion for degenerative lumbar scoliosis: a retrospective cohort study.Quantitative imaging in medicine and surgery · 2023Article
- Treatment of degenerative lumbar scoliosis using transforaminal lumbar interbody fusion based on the concept of intervertebral correction.International orthopaedics · 2023Article
- Does the use of postoperative brace help preventing mechanical complications following adult deformity surgery?European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023Article
- Biomechanical evaluation of multiple pelvic screws and multirod construct for the augmentation of lumbosacral junction in long spinal fusion surgery.Frontiers in bioengineering and biotechnology · 2023Article
- Rapidly destructive osteoarthritis of the spine: lessons learned from the first reported case.BMC musculoskeletal disorders · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeFour-rod instrumentation and interbody fusion may reduce mechanical complications in degenerative scoliosis surgery compared to 2-rod instrumentation. The purpose was to compare clinical results, sagittal alignment and mechanical complications with both techniques.
methodsFull spine radiographs were analysed in 97 patients instrumented to the pelvis: 58 2-rod constructs (2R) and 39 4-rod constructs (4R). Clinical scores (VAS, ODI, SRS-22, EQ-5D-3L) were assessed preoperatively, at 3 months, 1 year and last follow-up (average 4.2 years). Radiographic measurements were: thoracic kyphosis, lumbar lordosis, spinopelvic parameters, segmental lordosis distribution. The incidence of non-union and PJK were investigated.
resultsAll clinical scores improved significantly in both groups between preoperative and last follow-up. In the 2R-group, lumbar lordosis increased to 52.8° postoperatively and decreased to 47.0° at follow-up (p = 0.008). In the 4R-group, lumbar lordosis increased from 46.4 to 52.5° postoperatively and remained at 53.4° at follow-up. There were 8 (13.8%) PJK in the 2R-group versus 6 (15.4%) in the 4R-group, with a mismatch between lumbar apex and theoretic lumbar shape according to pelvic incidence. Non-union requiring revision surgery occurred on average at 26.9 months in 28 patients (48.3%) of the 2R-group. No rod fracture was diagnosed in the 4R-group.
conclusionMulti-level interbody fusion combined with 4-rod instrumentation decreased risk for non-union and revision surgery compared to select interbody fusion and 2-rod instrumentation. The role of additional rods on load sharing still needs to be determined when multiple cages are used. Despite revision surgery in the 2R group, final clinical outcomes were similar in both groups. LEVEL OF EVIDENCE: III.