Evidence map›Paper›PMID 33992093›Full record

ArticleBMC neurology2021

Endovascular treatment of vertebral and basilar artery aneurysms with low-profile visualized intraluminal support device.

Quanlong Hong, Wenqiang Li, Jing Ma, Peng Jiang, Yisen Zhang

Open access · goldAbstract read
In one paragraph

Article in BMC neurology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Quanlong Hong *Department of Neurology, The First Hospital of Quanzhou Affiliated to Fujian Medical University, Quanzhou, China.
Wenqiang Li *Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, NansanhuanXilu 119, Fengtai District, Beijing, 100070, China.
Jing MaDepartment of Echocardiography, Shanghai Xuhui Central Hospital, Zhongshan-Xuhui Hospital, Fudan University, Shanghai, China.
Peng JiangDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, NansanhuanXilu 119, Fengtai District, Beijing, 100070, China. jiangpeng33@126.com.
Yisen ZhangDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, NansanhuanXilu 119, Fengtai District, Beijing, 100070, China. zhangyisen@bjtth.org.
Beijing Institute of Neurosurgery · CNFirst Affiliated Hospital of Zhengzhou University · CNFudan University · CNFujian Medical University · CN

Funding

National Natural Science Foundation of China 81801158 and 81501483Shanghai Natural Science Foundation 18ZR1435400Youth Scientist Project of Beijing Tiantan Hospital YSP201904
6 · The paper itself

Abstract

backgroundThe Low-profile Visualized Intraluminal Support (LVIS) device is a self-expanding, nitinol, single-braid, closed-cell device that was recently developed for endovascular embolization of intracranial aneurysms. However, current knowledge regarding the use of LVIS devices to treat vertebral and basilar artery aneurysms is limited. We aimed to evaluate the feasibility, efficacy, and safety of the LVIS device for treating vertebral and basilar artery aneurysms.

methodsBetween January 2015 and December 2017, patients with vertebral and basilar artery aneurysms treated using LVIS stents were enrolled in this study. We analyzed patients' demographic, clinical and aneurysmal characteristics, procedural details, complications, and angiographic and clinical follow-up results.

resultsWe identified 63 patients with 64 vertebral and basilar artery aneurysms who underwent treatment with (n = 59) or without (n = 5) LVIS stenting, including 10 patients with ruptured aneurysms. Forty-one aneurysms were located at the vertebral artery, and 23 at the basilar artery. Intraprocedural-related complications developed in three (4.8%) patients, while none of these patients developed morbidities or died during follow-up. Three patients developed post-procedural complications (4.8%). Two patients experienced ischemic events immediately post-procedure. A minor permanent morbidity developed in one of the two patients (1.6%). The mortality rate was 1.6%, for that the patient died of brainstem hemorrhage after 1 month of follow-up. At a mean follow-up of 12.5 months, 39/43 (90.7%) patients had stable or improved aneurysms, and four (9.3%) had recanalized.

conclusionsLVIS device of vertebral and basilar artery aneurysms may be an acceptable safety profile and may represent a reasonable treatment option in the short-term. Long-term and larger cohort studies are necessary to validate our results.

Indexed as

AdultAneurysm, RupturedBasilar ArteryCerebral AngiographyCerebral HemorrhageEmbolization, TherapeuticEndovascular ProceduresFemaleHumansIntracranial AneurysmMaleMiddle AgedRetrospective StudiesStentsTreatment OutcomeVertebral Arterycomplications5Endovascular treatment4Low-profile visualized intraluminal support device 2stent3Vertebral and basilar artery aneurysms1

Identifiers

PMID33992093
PMCPMC8122564
OpenAlexW3163106667

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.