Evidence map›Paper›PMID 33990213›Full record

ArticleBMC urology2021

Newly designed solid coupling medium for reducing trapped air pockets during extracorporeal shock wave lithotripsy_ a phantom study.

Chien-Sheng Wang, Ching-Chia Li, Wen-Jeng Wu, Wen-Chin Liou, Yusen Eason Lin, Wei-Chuan Chen

Open access · goldAbstract readComparative Study
In one paragraph

Article in BMC urology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Chien-Sheng WangDepartment of Urology, School of Medicine, College of Medicine, Kaohsiung Medical University Hospital, No.100, Shiquan 1st Rd., Sanmin Dist., Kaohsiung City 807, Taiwan.
Ching-Chia LiDepartment of Urology, School of Medicine, College of Medicine, Kaohsiung Medical University Hospital, No.100, Shiquan 1st Rd., Sanmin Dist., Kaohsiung City 807, Taiwan.
Wen-Jeng WuDepartment of Urology, School of Medicine, College of Medicine, Kaohsiung Medical University Hospital, No.100, Shiquan 1st Rd., Sanmin Dist., Kaohsiung City 807, Taiwan.
Wen-Chin LiouDepartment of Surgery, St. Joseph Hospital, Kaohsiung City, Taiwan.
Yusen Eason LinGraduate Institute of Human Resource and Knowledge Management, National Kaohsiung Normal University, Kaohsiung City, Taiwan.
Wei-Chuan ChenDepartment of Urology, School of Medicine, College of Medicine, Kaohsiung Medical University Hospital, No.100, Shiquan 1st Rd., Sanmin Dist., Kaohsiung City 807, Taiwan. coupe055@ms28.hinet.net.
Kaohsiung Medical University · TWNational Kaohsiung Normal University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAir pockets between the lithotripter head and body surface are almost inevitably generated when applying a handful of gel onto the contact portion of the treatment head and that on the patient's skin during coupling procedure. These air pockets can compromise the transmission of acoustic energy of shock wave and may significantly affect efficacy of stone disintegration. Comparing to conventional gel, this study aims to investigate efficacy of stone disintegration by using a proprietary isolation-coupling pad ("icPad") as the coupling medium to reduce trapped air pockets during ESWL procedure.

methodIn this phantom study, Dornier lithotripter (Delta-2 RC, Dornier MedTech Europe GmbH Co., Germany) was used with a proprietary gel pads (icPad, Diameter = 150 mm, Thickness = 4 mm and 8 mm). The lithotripter was equipped with inline camera to observe the trapped air pockets between the contact surface of the lithotripter head. A testing and measuring device were used to observe experimental stone disintegration using icPad and semi-liquid gel. The conventional semi-liquid gel was used as control for result comparison.

resultsThe stone disintegration rate of icPad 4 mm and 8 mm after 200 shocks of energy at level 2 were significantly higher than that of the semi-liquid gel (disintegration rate 92.3%, 85.0% vs. 45.5%, respectively, p < 0.001). The number of shocks for complete stone disintegration by icPad of 4 mm and 8 mm at the same energy level 2 were significantly lower than that of the semi-liquid gel (the number of shocks 242.0 ± 13.8, 248.7 ± 6.3 vs. 351.0 ± 54.6, respectively, p = 0.011). Furthermore, quantitative comparison of observed air pockets under Optical Coupling Control (OCC) system showed that the area of air pockets in semi-liquid group was significantly larger than that of the group using icPad (8 mm) and that of the group using icPad (8 mm) after sliding (332.7 ± 91.2 vs. 50.3 ± 31.9, 120.3 ± 21.5, respectively, p < 0.05).

conclusionThe advantages of icPad includes: (1) reduced the numbers of shock wave and increased stone disintegration rate due to icPad's superior efficacy; (2) significantly reduce trapped air pockets in ESWL coupling. Due to the study limitation, more data are needed to confirm our observations before human trials.

Indexed as

GelsAirHumansLithotripsyPhantoms, ImagingGelsAir pocketsCouplingExtracorporeal shock wave lithotripter

Identifiers

PMID33990213
PMCPMC8120698
OpenAlexW3160916015

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.