Evidence map›Paper›PMID 33988801›Full record

ArticleThe international journal of cardiovascular imaging2021

Implantation depth and its influence on complications after TAVI with self-expanding valves.

Philipp Breitbart, Jan Minners, Manuel Hein, Holger Schröfel, Franz-Josef Neumann, Philipp Ruile

Open access · hybridAbstract read
In one paragraph

Article in The international journal of cardiovascular imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Philipp BreitbartDivision of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Südring 15, 79189, Bad Krozingen, Germany. Philipp.Breitbart@universitaets-herzzentrum.de.ORCID http://orcid.org/0000-0002-7390-5287
Jan MinnersDivision of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Südring 15, 79189, Bad Krozingen, Germany.
Manuel HeinDivision of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Südring 15, 79189, Bad Krozingen, Germany.
Holger SchröfelDivision of Cardiovascular Surgery, University Heart Center Freiburg-Bad Krozingen, Bad Krozingen, Germany.
Franz-Josef NeumannDivision of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Südring 15, 79189, Bad Krozingen, Germany.
Philipp RuileDivision of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Südring 15, 79189, Bad Krozingen, Germany.
Universitäts-Herzzentrum Freiburg-Bad Krozingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Prior studies in patients with transcatheter aortic valve implantation (TAVI) demonstrated an influence of transcatheter heart valve (THV) position on the occurrence of new conductions disturbances (CD) and paravalvular leakage (PVL) post TAVI in balloon-expandable valves (BEV). Purpose of this study was to investigate the THV implantation depth and its influence on the occurrence of CD and PVL in self-expanding valves (SEV). We performed fusion imaging of pre- and post-procedural computed tomography angiography in 104 TAVI-patients (all with Evolut R) to receive a 3-D reconstruction of the THV within the native annulus region. The THV length below the native annulus was measured for assessment of implantation depth. Electrocardiograms pre-discharge were assessed for conduction disturbances (CD), PVL was determined in transthoracic echocardiography. The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm. Using the best cut-off of ≥ 4 mm in receiver operating characteristic curve analysis (sensitivity 83.3%, specificity 60.0%) patients with lower THV position developed more new CD after TAVI (68.2 vs. 23.7%, P < 0.001). A deep THV position was identified as the only predictor for new CD after TAVI (odds ratio [CI] 1.312[1.119-1.539], P = 0.001). The implantation depth showed no influence on the grade of PVL (r = 0.052, P = 0.598). In patients with TAVI using the Evolut R SEV, a lower THV positioning (≥ 4 mm length below annulus) was a predictor for new conduction disturbances. In contrast, implantation depth was not associated with the extent of PVL. Prostheses positions of self-expanding valves and their influence on the occurrence of new conduction disturbances and the grade of paravalvular leakage after TAVI.

Indexed as

Aortic Valve StenosisHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementAortic ValveHumansPredictive Value of TestsProsthesis DesignRetrospective StudiesTreatment OutcomeComputed tomography angiographyFusion imagingSelf-expanding valve typesTAVITAVI complicationsTHV positioning

Identifiers

PMID33988801
PMCPMC8494692
OpenAlexW3163424284

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked