Evidence map›Paper›PMID 33987701›Full record

ArticleAnalytical and bioanalytical chemistry2021

Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration.

Huu-Hien Huynh, Amandine Bœuf, Maxence Derbez-Morin, Anne-Marie Dupuy, Béatrice Lalere, Vincent Delatour, Joëlle Vinh

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Huu-Hien HuynhBiomedical and Organic Chemistry Department, Laboratoire National de Métrologie et d'Essais (LNE), Paris, France.
Amandine BœufBiomedical and Organic Chemistry Department, Laboratoire National de Métrologie et d'Essais (LNE), Paris, France. amandine.boeuf@lne.fr.ORCID http://orcid.org/0000-0002-3104-6015
Maxence Derbez-MorinBiomedical and Organic Chemistry Department, Laboratoire National de Métrologie et d'Essais (LNE), Paris, France.
Anne-Marie DupuyLaboratoire de Biochimie et Hormonologie, CHU Montpellier, Université Montpellier 1, Montpellier, France.
Béatrice LalereBiomedical and Organic Chemistry Department, Laboratoire National de Métrologie et d'Essais (LNE), Paris, France.
Vincent DelatourBiomedical and Organic Chemistry Department, Laboratoire National de Métrologie et d'Essais (LNE), Paris, France.
Joëlle VinhBiological Mass Spectrometry and Proteomics, SMBP, ESPCI Paris, Université PSL, CNRS FRE2032, Paris, France.
Laboratoire National de Métrologie et d'Essais · FRCentre National de la Recherche Scientifique · FRCommissariat à l'Énergie Atomique et aux Énergies Alternatives · FRUniversité de Montpellier · FR

Funding

European Metrology Programme for Innovation and Research (EMPIR) 18HLT03
6 · The paper itself

Abstract

The quantification of low abundant proteins in complex matrices by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) remains challenging. A measurement procedure based on optimized antibody-free sample preparation and isotope dilution coupled to LC-MS/MS was developed to quantify procalcitonin (PCT) in human serum at sub-microgram per liter level. A combination of sodium deoxycholate-assisted protein precipitation with acetonitrile, solid-phase extraction, and trypsin digestion assisted with Tween-20 enhanced the method sensitivity. Linearity was established through peptide-based calibration curves in the serum matrix (0.092-5.222 μg/L of PCT) with a good linear fit (R2 ≥ 0.999). Quality control materials spiked with known amounts of protein-based standards were used to evaluate the method's accuracy. The bias ranged from -2.6 to +4.3%, and the intra-day and inter-day coefficients of variations (CVs) were below 2.2% for peptide-based quality controls. A well-characterized correction factor was determined and applied to compensate for digestion incompleteness and material loss before the internal standards spike. Results with metrological traceability to the SI units were established using standard peptide of well-characterized purity determined by peptide impurity corrected amino acid analysis. The validated method enables accurate quantification of PCT in human serum at a limit of quantification down to 0.245 μg/L (bias -1.9%, precision 9.1%). The method was successfully applied to serum samples obtained from patients with sepsis. Interestingly, the PCT concentration reported implementing the isotope dilution LC-MS/MS method was twofold lower than the concentration provided by an immunoassay.

Indexed as

Amino Acid SequenceCalcitoninCalibrationChromatography, LiquidHumansMass SpectrometryProcalcitoninSensitivity and SpecificitySerumCalcitoninProcalcitoninIsotope dilution mass spectrometryPeptide-based calibrationProcalcitoninSepsis

Identifiers

PMID33987701
OpenAlexW3162985141

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.