Evidence map›Paper›PMID 33987365›Full record

ArticleAnnals of translational medicine2021

Computational numerical analysis of different cannulation methods during cardiopulmonary bypass of type A aortic dissection model based on computational fluid dynamics.

Li Deng, Hao Qin, Zhiyuan Guan, Qingchun Mu, Qingping Xia, Maosheng Wang, Wen-Hua Huang, Kaiyun Gu

Erratum issuedOpen access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. CarotidWorld journal of cardiology · 2024
    Article
  3. Review
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Li DengAffiliated Gaozhou Hospital of Guangdong Medical University, Gaozhou, China.
Hao QinClinical Research Center of Digital Medicine and 3D Printing, Department of Cardiovascular Surgery, The People's Hospital of Gaozhou, Gaozhou, China.
Zhiyuan GuanPeking University Third Hospital, Beijing, China.
Qingchun MuClinical Research Center of Digital Medicine and 3D Printing, Department of Cardiovascular Surgery, The People's Hospital of Gaozhou, Gaozhou, China.
Qingping XiaClinical Research Center of Digital Medicine and 3D Printing, Department of Cardiovascular Surgery, The People's Hospital of Gaozhou, Gaozhou, China.
Maosheng WangClinical Research Center of Digital Medicine and 3D Printing, Department of Cardiovascular Surgery, The People's Hospital of Gaozhou, Gaozhou, China.
Wen-Hua HuangOrthopaedic Center, Affiliated Hospital of Guangdong Medical University, Guangdong Medical University, Zhanjiang, China.
Kaiyun GuNational Clinical Research Center for Child Health, The Children's Hospital Zhejiang University School of Medicine, Hangzhou, China.
Gaozhou People's Hospital · CNGuangdong Medical College · CNChildren's Hospital of Zhejiang University · CNPeking University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of the present study was to use a numerical simulation based on computational fluid dynamics (CFD) to analyze the difference of different cannulation methods on hemodynamics characteristic in a type A aortic dissection (TAAD) model.

methodsA finite-element analysis based on the CFD model of a TAAD patient was used, and axillary artery cannulation (AAC), innominate artery cannulation (IAC), and femoral artery cannulation (FAC) were analyzed under different situations, including a cardiac output (CO) of 2.5 L/min and cardiopulmonary bypass (CPB) of 2.5 L/min (partial CPB before cross-clamping aorta, defined as condition A), and a CO of 0 L/min and CPB of 5 L/min (aortic cross-clamping phase, defined as condition B). The insertion of an 8-mm cannula into the different models was simulated. Hemodynamic characteristics, including wall shear stress, wall stress, blood flow, and velocity were analyzed.

resultsIn condition A, the total flow of branches of the aortic arch was 2,009.5 mL/min (AAC), 1,855.47 mL/min (IAC), and 1,648.03 mL/min (FAC). All cannulation methods improved left renal blood perfusion. However, in relation to blood flow in the right renal artery, FAC showed the highest blood flow (105 mL/min). The results in condition B were similar to those of condition A. The velocity, shear stress, and stress of entry tear via AAC and IAC decreased in condition B compared with condition A. The velocity, shear stress, stress of tear via AAC was lower than that of IAC.

conclusionsDifferent cannulation modes have an effect on the hemodynamic characteristic of the tear, but this effect is related to different states of CPB. AAC was found to superior to IAC, especially in reducing velocity, stress, and shear stress of site of tear. However, IAC and AAC are more conductive to blood supply than FAC in branch vessels of the aortic arch without being affected by the CPB state.

Indexed as

aortic dissectioncannulationcomputational fluid dynamics (CFD)Hemodynamics

Identifiers

PMID33987365
PMCPMC8106110
OpenAlexW3153873104

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked