Evidence map›Paper›PMID 33987234›Full record

ArticleAnnals of translational medicine2021

A four-year observation of corneal densitometry after implantable collamer lens V4c implantation.

Jing Zhao, Wen Yang, Jiao Zhao, Yang Shen, Ling Sun, Tian Han, Xiaoying Wang, Peijun Yao, Xingtao Zhou

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 1 country.

Jing ZhaoEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Wen YangDepartment of Ophthalmology, The Third People's Hospital of Chengdu, The Affiliated Hospital of Southwest Jiaotong University, Chengdu, China.
Jiao ZhaoDepartment of Ophthalmology, People's Hospital of Leshan, Leshan, China.
Yang ShenEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Ling SunEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Tian HanEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Xiaoying WangEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Peijun YaoEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Xingtao ZhouEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Eye & ENT Hospital of Fudan University · CNFudan University · CNChinese Academy of Medical Sciences & Peking Union Medical College · CNShanghai Clinical Research Center · CNSouthwest Jiaotong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo observe the changes in corneal densitometry (CD) with a Pentacam after implantable collamer lens (ICL) V4c implantation in myopia patients, and to investigate potential influencing factors.

methodsWe reviewed 65 eyes of 33 patients (mean age, 29.08±5.54 years) with myopia or myopic astigmatism who underwent ICL V4c implantation. Clinic parameters and Pentacam images of corneal topography and CD were obtained pre- and postoperatively.

resultsAfter an average of 52±2.2 months follow-up, the efficacy and safety indexes assessed at the last follow-up were 1.03±0.18 and 1.21±0.21, respectively. Except in the central annular zone of 0-2 mm, the CD values increased significantly at postoperative day 1 and decreased significantly until postoperative 1 year (P<0.05). The increase in CD values at different annular zones at postoperative day 1 was ranked as: 0-2 mm <2-6 mm < 6-10 mm. No significant difference was observed in corneal density at 1 week, 1 month, and 1-year follow-up when compared with the preoperative value (P>0.05). The CD value at 4 years follow-up increased significantly and correlated positively with age and preoperative uncorrected distance visual acuity, and negatively with preoperative spherical equivalent and intraocular pressure (IOP) (P<0.05).

conclusionsICL V4c implantation demonstrated safety and efficacy for myopia correction. The CD value increased at 4 years postoperatively and correlated with age, preoperative spherical equivalent, uncorrected distance visual acuity, and IOP.

Indexed as

corneal densitometry (CD)Implantable collamer lens (ICL)Pentacamsafety

Identifiers

PMID33987234
PMCPMC8105832
OpenAlexW3133810482

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.