ArticleComputational and mathematical methods in medicine2021
The Hemodynamics of Patent Ductus Arteriosus in Patients after Central Shunt Operation.
Article in Computational and mathematical methods in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Multiscale Modeling Is Required for the Patent Ductus Arteriosus in Preterm Infants.Frontiers in pediatrics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A central shunt (CS) was an important surgery of systemic-to-pulmonary shunt (SPS) for the treatment of complex congenital heart diseases with decreased pulmonary blood flow (CCHDs-DPBF). There was no clear conclusion on how to deal with unclosed patent ductus arteriosus (PDA) during CS surgery. This study expanded the knowledge base on PDA by exploring the influence of the closing process of the PDA on the hemodynamic parameters for the CS model. The initial three-dimensional (3D) geometry was reconstructed based on the patient's computed tomography (CT) data. Then, a CS configuration with three typical pulmonary artery (PA) dysplasia structures and different sizes of PDA was established. The three-element windkessel (3WK) multiscale coupling model was used to define boundary conditions for transient simulation through computational fluid dynamics (CFD). The results showed that the larger size of PDA led to a greater systemic-to-pulmonary shunt ratio (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.