Evidence map›Paper›PMID 33980186›Full record

ArticleBMC pulmonary medicine2021

A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis.

Kevin J O'Sullivan, Valerie Power, Barry Linnane, Deirdre McGrath, Magdalena Mulligan, Rebecca White, Leonard W O'Sullivan, Colum P Dunne

Open access · goldAbstract read
In one paragraph

Article in BMC pulmonary medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Clinimetric properties of field exercise tests in cystic fibrosis: a systematic review.European respiratory review : an official journal of the European Respiratory Society · 2024
    Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Kevin J O'SullivanRapid Innovation Unit - University of Limerick, Limerick, Ireland.
Valerie PowerRapid Innovation Unit - University of Limerick, Limerick, Ireland.
Barry LinnaneSchool of Medicine, University of Limerick, Limerick, Ireland.
Deirdre McGrathSchool of Medicine, University of Limerick, Limerick, Ireland.
Magdalena MulliganSchool of Medicine, University of Limerick, Limerick, Ireland.
Rebecca WhitePaediatric Cystic Fibrosis Department, University Hospital Limerick, Limerick, Ireland.
Leonard W O'SullivanRapid Innovation Unit - University of Limerick, Limerick, Ireland.
Colum P DunneSchool of Medicine, University of Limerick, Limerick, Ireland. colum.dunne@ul.ie.
University of Limerick · IEUniversity Hospital Limerick · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOscillating Positive Expiratory Pressure (OPEP) devices are important adjuncts to airway clearance therapy in patients with cystic fibrosis (CF). Current devices are typically reusable and require daily, or often more frequent, cleaning to prevent risk of infection by acting as reservoirs of potentially pathogenic organisms. In response, a daily disposable OPEP device, the UL-OPEP, was developed to mitigate the risk of contamination and eliminate the burdensome need for cleaning devices.

methodsA convenience sample of 36 participants, all current OPEP device users, was recruited from a paediatric CF service. For one month, participants replaced their current OPEP device with a novel daily disposable device. Assessment included pre- and post-intervention lung function by spirometry, as well as Lung Clearance Index. Quality of life was assessed using the Cystic Fibrosis Questionnaire - Revised, while user experience was evaluated with a post-study survey.

results31 participants completed the study: 18 males; median age 10 years, range 4-16 years. Lung function (mean difference ± SD, %FEV1 = 1.69 ± 11.93; %FVC = 0.58 ± 10.04; FEV1: FVC = 0.01 ± 0.09), LCI (mean difference ± SD, 0.08 ± 1.13), six-minute walk test, and CFQ-R were unchanged post-intervention. Participant-reported experiences of the device were predominantly positive.

conclusionsThe disposable OPEP device maintained patients' lung function during short term use (≤ 1 month), and was the subject of positive feedback regarding functionality while reducing the risk of airway contamination associated with ineffective cleaning. REGISTRATION: The study was approved as a Clinical Investigation by the Irish Health Products Regulatory Authority (CRN-2209025-CI0085).

Indexed as

AdolescentChest Wall OscillationChildChild, PreschoolCohort StudiesCystic FibrosisFemaleForced Expiratory VolumeHumansLungMaleMucociliary ClearancePhysical Therapy ModalitiesPositive-Pressure RespirationQuality of LifeOscillating positive expiratory pressure therapy; Cystic fibrosis; Hypersecretion; Airway clearance; Paediatric

Identifiers

PMID33980186
PMCPMC8114193
OpenAlexW3160954865

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.