Evidence map›Paper›PMID 33977313›Full record

ReviewArchives of orthopaedic and trauma surgery2022

Use of intramedullary locking nail for displaced intraarticular fractures of the calcaneus: what is the evidence?

Alessio Bernasconi, Paolino Iorio, Yaser Ghani, Miltiadis Argyropoulos, Shelain Patel, Alexej Barg, Francesco Smeraglia, Giovanni Balato, Matthew Welck

Abstract readReview
PubMed Publisher
In one paragraph

Review in Archives of orthopaedic and trauma surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
2.0field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. [Calcaneal fractures-Current status and treatment approaches].Unfallchirurgie (Heidelberg, Germany) · 2026
    Review
  5. Article
  6. Functional outcomes after intramedullary nailing (C-Nail®) of severe calcaneal fractures with mean follow-up of 36 months.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 4 countries.

Alessio BernasconiDepartment of Public Health, Trauma and Orthopaedics, University of Naples Federico II, Naples, Italy. alebernas@gmail.com.ORCID http://orcid.org/0000-0002-9427-3178
Paolino IorioDepartment of Public Health, Trauma and Orthopaedics, University of Naples Federico II, Naples, Italy.
Yaser GhaniFoot and Ankle Unit, Royal National Orthopaedic Hospital, Stanmore, UK.
Miltiadis ArgyropoulosFoot and Ankle Unit, Royal National Orthopaedic Hospital, Stanmore, UK.
Shelain PatelFoot and Ankle Unit, Royal National Orthopaedic Hospital, Stanmore, UK.
Alexej BargDepartment of Orthopaedics, Trauma and Reconstructive Surgery, University Medical Center Hamburg-Eppendorf, Hamburg , Germany.
Francesco SmeragliaDepartment of Public Health, Trauma and Orthopaedics, University of Naples Federico II, Naples, Italy.
Giovanni BalatoDepartment of Public Health, Trauma and Orthopaedics, University of Naples Federico II, Naples, Italy.
Matthew WelckFoot and Ankle Unit, Royal National Orthopaedic Hospital, Stanmore, UK.
Royal National Orthopaedic Hospital · GBUniversity of Naples Federico II · ITUniversität Hamburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIntramedullary locking devices (ILDs) have recently been advocated as a minimally invasive approach to manage displaced intraarticular calcaneal fractures (DIACFs), to minimise complications and improve outcomes. We reviewed clinical and biomechanical studies dealing with commercially available devices to identify their characteristics, efficacy and safety.

methodsFollowing a PRISMA checklist, Medline, Scopus and EMBASE databases were searched to identify studies reporting the use of ILDs for treating DIACFs. Biomechanical studies were first evaluated. Cohort studies were then reviewed for demographics, surgical technique, postoperative protocol, clinical and radiographic scores, complications and reoperations. The modified Coleman Methodology Score (CMS) was used to assess the quality of studies.

resultsEleven studies were identified which investigated two devices (Calcanail®, C-Nail®). Three biomechanical studies proved they offered adequate primary stability, stiffness, interfragmentary motion and load to failure. Eight clinical studies (321 feet, 308 patients) demonstrated a positive clinical and radiographic outcome at 16-months average follow-up. Metalware irritation (up to 20%) and temporary nerve entrapment symptoms (up to 30%) were the most common complications, while soft tissue issues (wound necrosis, delayed healing, infection) were reported in 3-5% of cases. Conversion to subtalar fusion was necessary in up to 6% of cases. Four (50%) out of 8 studies were authored by implant designers and in 5 (62%) relevant conflicts of interest were disclosed. Mean (± standard deviation) CMS was 59 ± 9.8, indicating moderate quality.

conclusionsTreating DIAFCs with ILDs leads to satisfactory clinical outcomes at short-term follow-up, enabling restoration of calcaneal height and improved subtalar joint congruency. Metalware irritation and temporary nerve entrapment symptoms are common complications although wound complications are less frequent than after open lateral approaches. The quality of evidence provided so far is moderate and potentially biased by the conflict of interest, raising concerns about the generalisability of results. LEVEL OF EVIDENCE: Level V - Review of Level III to V studies.

Indexed as

CalcaneusFractures, BoneIntra-Articular FracturesNerve Compression SyndromesFracture Fixation, InternalHumansTreatment OutcomeCalcanailCalcaneusDisplacedFractureNailSubtalar

Identifiers

PMID33977313
OpenAlexW3160848046

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.