Evidence map›Paper›PMID 33977264›Full record

ArticleBrain communications2021

Pre-treatment of blood samples reveal normal blood hypocretin/orexin signal in narcolepsy type 1.

Helene M Ægidius, Lars Kruse, Gitte L Christensen, Marc P Lorentzen, Niklas R Jørgensen, Monica Moresco, Fabio Pizza, Giuseppe Plazzi, Poul J Jennum, Birgitte R Kornum

Open access · goldAbstract read
In one paragraph

Article in Brain communications, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 2 countries.

Helene M ÆgidiusDepartment of Neuroscience, University of Copenhagen, 2200 Copenhagen N, Denmark.
Lars KruseDepartment of Clinical Biochemistry, Rigshospitalet, 2600 Glostrup, Denmark.
Gitte L ChristensenDepartment of Clinical Biochemistry, Rigshospitalet, 2600 Glostrup, Denmark.
Marc P LorentzenDepartment of Clinical Biochemistry, Rigshospitalet, 2600 Glostrup, Denmark.
Niklas R JørgensenDepartment of Clinical Biochemistry, Rigshospitalet, 2600 Glostrup, Denmark.
Monica MorescoIstituto delle Scienze Neurologiche, Ospedale Bellaria, IRCCS Bologna, 40139 Bologna, Italy.
Fabio PizzaIstituto delle Scienze Neurologiche, Ospedale Bellaria, IRCCS Bologna, 40139 Bologna, Italy.
Giuseppe PlazziIstituto delle Scienze Neurologiche, Ospedale Bellaria, IRCCS Bologna, 40139 Bologna, Italy.
Poul J JennumDepartment of Clinical Neurophysiology, Danish Center for Sleep Medicine, Rigshospitalet, 2600 Glostrup, Denmark.
Birgitte R KornumDepartment of Neuroscience, University of Copenhagen, 2200 Copenhagen N, Denmark.ORCID https://orcid.org/0000-0002-2515-9451
Rigshospitalet · DKOspedale Bellaria · ITUniversity of Copenhagen · DKGlostrup Hospital · DKUniversity of Modena and Reggio Emilia · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The hypocretin/orexin system regulates arousal through central nervous system mechanisms and plays an important role in sleep, wakefulness and energy homeostasis. It is unclear whether hypocretin peptides are also present in blood due to difficulties in measuring reliable and reproducible levels of the peptides in blood samples. Lack of hypocretin signalling causes the sleep disorder narcolepsy type 1, and low concentration of cerebrospinal fluid hypocretin-1/orexin-A peptide is a hallmark of the disease. This measurement has high diagnostic value, but performing a lumbar puncture is not without discomfort and possible complications for the patient. A blood-based test to assess hypocretin-1 deficiency would therefore be of obvious benefit. We here demonstrate that heating plasma or serum samples to 65°C for 30 min at pH 8 significantly increases hypocretin-1 immunoreactivity enabling stable and reproducible measurement of hypocretin-1 in blood samples. Specificity of the signal was verified by high-performance liquid chromatography and by measuring blood samples from mice lacking hypocretin. Unspecific background signal in the assay was high. Using our method, we show that hypocretin-1 immunoreactivity in blood samples from narcolepsy type 1 patients does not differ from the levels detected in control samples. The data presented here suggest that hypocretin-1 is present in the blood stream in the low picograms per millilitres range and that peripheral hypocretin-1 concentrations are unchanged in narcolepsy type 1.

Indexed as

hypocretinnarcolepsy type 1orexinplasma hypocretin-1radioimmunoassay

Identifiers

PMID33977264
PMCPMC8100001
OpenAlexW3139462475

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.