Evidence map›Paper›PMID 33974785›Full record

ArticleEar and hearing

Audiologic Profiles of Children With Otitis Media With Effusion.

Sarah Al-Salim, Richard M Tempero, Hannah Johnson, Gabrielle R Merchant

Open access · greenAbstract read
In one paragraph

Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.5field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 28 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Wideband Tympanometry (WBT) Features in Children with Cleft Palate and Otitis Media with Effusion Before and After Cleft Palate Surgery.Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India · 2023
    Article
  6. Article
  7. Observational
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Sarah Al-SalimCenter for Childhood Deafness, Language and Learning, Boys Town National Research Hospital, Omaha, Nebraska, USA.
Richard M TemperoDepartment of Otolaryngology, Boys Town National Research Hospital, Omaha, Nebraska, USA.
Hannah JohnsonDepartment of Research, Boys Town National Research Hospital, Omaha, Nebraska, USA.
Gabrielle R MerchantDepartment of Research, Boys Town National Research Hospital, Omaha, Nebraska, USA.
Boys Town National Research Hospital · US

Funding

The Impact of Mild Hearing Loss on Auditory Perception in Complex EnvironmentsP20GM109023 · NIGMS · FATHER FLANAGAN'S BOYS' HOME · PI MCGREGOR, KARLA · 2014 to 2023
$23.4M
Research Synergy CoreP30DC004662 · NIDCD · FATHER FLANAGAN'S BOYS' HOME · PI GORGA, MICHAEL P. · 2001 to 2015
$5.9M
NIDCD NIH HHS P30 DC004662NIGMS NIH HHS P20 GM109023
6 · The paper itself

Abstract

objectivesTo describe the impact of effusion volume, viscosity, and purulence on the audiologic profiles of children with otitis media with effusion.

designFifty-one ears from children between the ages of 8 months and 11 years who had a diagnosis of otitis media with effusion and were scheduled for tympanostomy tube placement were recruited from medical clinics. The control group consisted of 17 ears from children between the ages of 10 months and 11 years without a recent history of otitis media and were recruited from a database of research volunteers. Participants received a comprehensive audiologic testing battery consisting of tympanometry, otoacoustic emissions, behavioral audiometric thresholds, and auditory brainstem response testing. For children with otitis media, this testing battery occurred 1 to 2 days before surgery. Middle ear effusions were characterized and collected on the day of surgery during tympanostomy tube placement from ears with otitis media with effusion. The comprehensive audiologic testing battery was completed postoperatively as well for most participants.

resultsEffusion volume, categorized in each ear as clear, partial, or full, effected the audiologic results. Ears with full effusions had moderate hearing losses, few to no measurable otoacoustic emissions, and delayed Wave V latencies. Ears with partial effusions and clear ears both had slight to mild hearing losses and normal Wave V latencies, though ears with partial effusions had fewer measurable otoacoustic emissions than clear ears. Normal-hearing control ears with no recent history of otitis media with effusion demonstrated normal audiometric thresholds, present otoacoustic emissions, and normal Wave V latencies. Repeat postoperative testing demonstrated improvements in audiologic testing results for all of the otitis media with effusion volume groups, with no significant differences remaining between the three otitis media with effusion groups. However, significant differences between otitis media with effusion ears and normal-hearing control ears persisted postoperatively, with otitis media with effusion ears demonstrating significantly poorer audiometric thresholds and reduced otoacoustic emissions as compared to normal control ears. The effect of effusion viscosity and purulence could not be systematically evaluated because minimal variability in effusion viscosity and purulence was observed in our sample, with nearly all effusions being mucoid and nonpurulent.

conclusionsEffusion volume observed at the time of tympanostomy tube surgery was found to play a significant role in outcomes and responses on a range of audiologic tests that compose the standard clinical pediatric audiologic assessment battery. Full middle ear effusions were associated with a moderate hearing loss, and few to no measurable otoacoustic emissions were detected. Ears with a recent diagnosis of otitis media with effusion but clear at the time of tympanostomy tube placement had less hearing loss and a greater number of present otoacoustic emissions than ears with full or partial effusions but were still found to have poorer hearing sensitivity than the healthy control ears. Differences between ears with otitis media with effusion and healthy control ears persisted on postoperative assessments of otoacoustic emissions and audiometric thresholds, though there were no remaining effects of the presurgical effusion volume group.

Indexed as

Otitis MediaOtitis Media with EffusionAcoustic Impedance TestsAudiometryChildHumansInfantMiddle Ear Ventilation

Identifiers

PMID33974785
PMCPMC8387329
OpenAlexW3150631790

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.