Evidence map›Paper›PMID 33973860›Full record

ArticleJMIR mHealth and uHealth2021

Feasibility of a Waistband-Type Wireless Wearable Electrocardiogram Monitoring System Based on a Textile Electrode: Development and Usability Study.

Danbi Gwon, Hakyung Cho, Hangsik Shin

Open access · goldAbstract read
In one paragraph

Article in JMIR mHealth and uHealth, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Danbi GwonDepartment of Biomedical Engineering, Chonnam National University, Yeosu, Republic of Korea.ORCID 0000-0002-7853-3638
Hakyung Cho *BLACKYAK Co Ltd, Seoul, Republic of Korea.ORCID 0000-0003-4521-1699
Hangsik Shin *Department of Biomedical Engineering, Chonnam National University, Yeosu, Republic of Korea.ORCID 0000-0002-3353-0310
Chonnam National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundElectrocardiogram (ECG) monitoring in daily life is essential for effective management of cardiovascular disease, a leading cause of death. Wearable ECG measurement systems in the form of clothing have been proposed to replace Holter monitors used for clinical ECG monitoring; however, they have limitations in daily use because they compress the upper body and, in doing so, cause discomfort during wear.

objectiveThe purpose of this study was to develop a wireless wearable ECG monitoring system that includes a textile ECG electrode that can be applied to the lining of pants and can be used in the same way that existing lower clothing is worn, without compression to the upper body.

methodsA textile electrode with stretchable characteristics was fabricated by knitting a conductive yarn together with polyester-polyurethane fiber, which was then coated with silver compound; an ECG electrode was developed by placing it on an elastic band in a modified limb lead configuration. In addition, a system with analog-to-digital conversion, wireless communication, and a smartphone app was developed, allowing users to be able to check and store their own ECGs in real time. A signal processing algorithm was also developed to remove noise from the obtained signal and to calculate the heart rate. To evaluate the ECG and heart rate measurement performance of the developed module, a comparative evaluation with a commercial device was performed. ECGs were measured for 5 minutes each in standing, sitting, and lying positions; the mean absolute percentage errors of heart rates measured with both systems were then compared.

resultsThe system was developed in the form of a belt buckle with a size of 53 × 45 × 12 mm (width × height × depth) and a weight of 23 g. In a qualitative evaluation, it was confirmed that the P-QRS-T waveform was clearly observed in ECGs obtained with the wearable system. From the results of the heart rate estimation, the developed system could track changes in heart rate as calculated by a commercial ECG measuring device; in addition, the mean absolute percentage errors of heart rates were 1.80%, 2.84%, and 2.48% in the standing, sitting, and lying positions, respectively.

conclusionsThe developed system was able to effectively measure ECG and calculate heart rate simply through being worn as existing clothing without upper body pressure. It is anticipated that general usability can be secured through further evaluation under more diverse conditions.

Indexed as

ElectrocardiographyWearable Electronic DevicesElectrodesFeasibility StudiesHumansTextileselectrocardiogrammobile phonesmartphonetelehealthtelemetrytelemonitoringtextile electrodewearable system

Identifiers

PMID33973860
PMCPMC8150414
OpenAlexW3156351299

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.