Evidence map›Paper›PMID 33971840›Full record

ArticleBMC musculoskeletal disorders2021

Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone.

Yung-Cheng Chiu, Cheng-En Hsu, Tsung-Yu Ho, Yen-Nien Ting, Ming-Tzu Tsai, Jui-Ting Hsu

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Yung-Cheng Chiu *School of Medicine, China Medical University, Taichung, 404, Taiwan.
Cheng-En Hsu *Department of Orthopaedics, Taichung Veterans General Hospital, Taichung, 407, Taiwan.
Tsung-Yu HoDepartment of Orthopedic Surgery, China Medical University Hospital, Taichung, 404, Taiwan.
Yen-Nien Ting3D Printing Medical Research Center, China Medical University Hospital, Taichung, 404, Taiwan.
Ming-Tzu TsaiDepartment of Biomedical Engineering, Hungkuang University, Taichung, 433, Taiwan, ROC.
Jui-Ting HsuSchool of Dentistry, College of Dentistry, China Medical University, Taichung, 404, Taiwan. jthsu@mail.cmu.edu.tw.
China Medical University · TWChina Medical University Hospital · TWHungkuang University · TWTaichung Veterans General Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMetacarpal shaft fractures are a common type of hand fracture. Despite providing strong fixation strength, plate fixation has numerous shortcomings. Concerning internal fixation with Kirschner wires (K-wires), although this approach is frequently used to treat metacarpal shaft fractures, the lack of functional stability may result in fixation failure.

objectiveTo evaluate the effect of figure-of-eight cerclage wire on fixation for transverse metacarpal shaft fractures using two K-wires. MATERIALS AND

methodsWe used a saw blade to create transverse metacarpal shaft fractures in 14 fourth-generation artificial third metacarpal bones (Sawbones, Vashon, WA, USA), which were assigned to groups undergoing fixation with two K-wires (KP) or with two K-wires and figure-of-eight cerclage wire (KP&F8). All specimens were subjected to material testing, specifically cantilever bending tests. The maximum fracture force and stiffness of the two fixation types were determined on the basis of the force-displacement data. The Mann-Whitney U test was used to compare between-group differences in maximum fracture force and stiffness.

resultsThe maximum fracture force of the KP group (median ± interquartile range = 97.30 ± 29.70 N) was significantly lower than that of the KP&F8 group (153.2 ± 69.50 N, p < 0.05; Figure 5a), with the median of the KP&F8 group exceeding that of the KP group by 57.5%. Similarly, stiffness was significantly lower in the KP group (18.14 ± 9.84 N/mm) than in the KP&F8 group (38.25 ± 23.49 N/mm; p < 0.05; Figure 5b), with the median of the KP&F8 group exceeding that of the KP group by 110.9%.

conclusionThe incorporation of a figure-of-eight cerclage wire increased the maximum fracture force and stiffness by 57.5 and 110.9%, respectively, compared with those achieved in standard two K-wire fixation. Therefore, hand surgeons are advised to consider the proposed approach to increase fixation strength.

Indexed as

Fractures, BoneMetacarpal BonesBone PlatesBone WiresFracture Fixation, InternalHumansFigure-of-eight cerclage wireK-wireMetacarpal shaft fracture

Identifiers

PMID33971840
PMCPMC8112006
OpenAlexW3161762280

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.