Evidence map›Paper›PMID 33964021›Full record

ArticleMedical physics2021

A prototype spatial-spectral CT system for material decomposition with energy-integrating detectors.

Matthew Tivnan, Wenying Wang, J Webster Stayman

Abstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Multimodal treatment and imaging of primary pulmonary artery sarcoma: a case report.American journal of nuclear medicine and molecular imaging · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Matthew TivnanJohns Hopkins University, 720 Rutland Ave., Traylor Building 605, Baltimore, MD, 21205, USA.
Wenying WangJohns Hopkins University, 720 Rutland Ave., Traylor Building 605, Baltimore, MD, 21205, USA.
J Webster StaymanJohns Hopkins University, 720 Rutland Ave., Traylor Building 605, Baltimore, MD, 21205, USA.

Funding

Spectral-spatial filtering for efficient multi-material decomposition in x-ray CTR21EB026849 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER · 2018 to 2019
$450k
HHS | National Institutes of Health (NIH) R21EB026849NIBIB NIH HHS R21 EB026849NIH HHS R21EB026849
6 · The paper itself

Abstract

purposeSpectral CT has great potential for a variety of clinical applications due to improved tissue and material discrimination over conventional single-energy CT. Many clinical and preclinical spectral CT systems have two spectral channels enabling dual-energy CT. Strategies include split filtration, dual-layer detectors, photon-counting detectors, and kVp switching. The motivation for this work is the development of an x-ray source spectral modulation device with three or more spectral channels to enable high-sensitivity multi-material decomposition with energy-integrating detectors. MATERIALS AND

methodsWe present spatial-spectral filters which are a new x-ray source modulation technology with the potential for additional channel diversity. The filtering device consists of an array of K-edge materials which divide the x-ray beam into spectrally varied beamlets. This design allows for an arbitrary number of spectral channels-trading off spatial and spectral information. We use a one-step model-based material decomposition (MBMD) algorithm to iteratively estimate material density images directly from the spatial-spectral CT data. In this work, we present a prototype spatial-spectral filter integrated with an x-ray CT test bench. The filter is composed of an array of tin, erbium, tantalum, and lead filter tiles which spatially modulate the system spectral sensitivity pattern. In a simulation study, we investigate the particular problem of mis-calibration between the data acquisition and the reconstruction model. With an understanding of the required model accuracy, we present a spectral calibration method to estimate the critical model parameters. To demonstrate feasibility of the spatial-spectral filter with a calibrated beamlet model, we collected a spatial-spectral CT scan of a multicontrast-enhanced phantom containing water, iodine, and gadolinium solutions.

resultsWith simulations, we show that material decomposition is possible with spatial-spectral-filtered CT data, and we demonstrate the importance of a well-calibrated physical model. We find a 50% increase in error for focal spot model mismatch of 0.27mm and gap width model mismatch of 16 mμ. With physical results, we demonstrate that the calibrated system model is in close agreement with the measured data, and that the reconstructed material density images match the ground truth concentrations for the multicontrast phantom. Empirical results indicate gadolinium density estimation had an error of 17-58% mostly due to a systematic constant bias of 0.30-0.60 mg/ml. Water density estimates are within 1% and iodine estimates are within 10% of ground truth.

conclusionThese preliminary results demonstrate the potential of spatial-spectral filters to enable multicontrast imaging. Moreover, this device is compatible with energy-integrating detectors and so provides a feasible modification to enable spectral CT imaging with existing single-energy systems.

Indexed as

IodineTomography, X-Ray ComputedCalibrationPhantoms, ImagingPhotonsIodinemodel-based material decompositionmulticontrast imagingmulti-energy CTsparse CTspectral CT

Identifiers

PMID33964021
PMCPMC13093246

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.