ArticleBrain communications2021
Objective interictal electrophysiology biomarkers optimize prediction of epilepsy surgery outcome.
Article in Brain communications, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 46 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
46 citing papers in PubMed.
- Naming-related spectral responses predict neuropsychological outcome after epilepsy surgery.Brain : a journal of neurology · 2022Trial
- Internal and external validation of comprehensive high-frequency activity biomarkers for epilepsy surgery.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2026Article
- Fully automated three-dimensional deep learning-based magnetic resonance imaging segmentation of brain cavities in epilepsy surgery.Epilepsia · 2026Article
- Discovering Novel intracranial EEG Biomarkers of Seizure Generating Tissue through Time-Frequency Analysis.medRxiv : the preprint server for health sciences · 2026Article
- Article
- Inroads into epilepsy through high-frequency oscillations: Achievements and benchmark areas for improvement.Epilepsia · 2026Review
- Internal and External Validation of Comprehensive High-Frequency Activity Biomarkers for Epilepsy Surgery.medRxiv : the preprint server for health sciences · 2025Article
- Self-supervised data-driven approach defines pathological high-frequency oscillations in epilepsy.Epilepsia · 2025Article
- PyHFO 2.0: an open-source platform for deep learning-based clinical high-frequency oscillations analysis.Journal of neural engineering · 2025Article
- Fractal Dimension in Healthy Hippocampi and Hippocampi With Mesial Temporal Sclerosis: An Observational Study.Cureus · 2025Article
- No association between histopathology and neurophysiology in surgical specimens from pediatric focal epilepsy patients.Epilepsia · 2025Article
- Localization of the Epileptogenic Zone Using Neural Spatial Volatility in Epilepsy Surgery.Neurology · 2025Observational
- AI-based localization of the epileptogenic zone using intracranial EEG.Epilepsia open · 2025Review
- Multi-centre normative brain mapping of intracranial EEG lifespan patterns in the human brain.Brain structure & function · 2025Article
- Dynamic Causal Tractography Analysis of Auditory Descriptive Naming: An Intracranial Study of 106 Patients.NeuroImage · 2025Article
- Visualization of functional and effective connectivity underlying auditory descriptive naming.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2025Article
- Fast ripple band high-frequency activity associated with thalamic sleep spindles in pediatric epilepsy.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2025Article
- Ictal phase-amplitude coupling as a biomarker for seizure onset zone in neocortical epilepsy.Frontiers in neurology · 2025Article
- Normative high-frequency oscillation phase-amplitude coupling and effective connectivity under sevoflurane.Brain communications · 2025Article
- Noninvasive classification of physiological and pathological high frequency oscillations in children.Brain communications · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Researchers have looked for rapidly- and objectively-measurable electrophysiology biomarkers that accurately localize the epileptogenic zone. Promising candidates include interictal high-frequency oscillation and phase-amplitude coupling. Investigators have independently created the toolboxes that compute the high-frequency oscillation rate and the severity of phase-amplitude coupling. This study of 135 patients determined what toolboxes and analytic approaches would optimally classify patients achieving post-operative seizure control. Four different detector toolboxes computed the rate of high-frequency oscillation at ≥80 Hz at intracranial EEG channels. Another toolbox calculated the modulation index reflecting the strength of phase-amplitude coupling between high-frequency oscillation and slow-wave at 3-4 Hz. We defined the completeness of resection of interictally-abnormal regions as the subtraction of high-frequency oscillation rate (or modulation index) averaged across all preserved sites from that averaged across all resected sites. We computed the outcome classification accuracy of the logistic regression-based standard model considering clinical, ictal intracranial EEG and neuroimaging variables alone. We then determined how well the incorporation of high-frequency oscillation/modulation index would improve the standard model mentioned above. To assess the anatomical variability across non-epileptic sites, we generated the normative atlas of detector-specific high-frequency oscillation and modulation index. Each atlas allowed us to compute the statistical deviation of high-frequency oscillation/modulation index from the non-epileptic mean. We determined whether the model accuracy would be improved by incorporating absolute or normalized high-frequency oscillation/modulation index as a biomarker assessing interictally-abnormal regions. We finally determined whether the model accuracy would be improved by selectively incorporating high-frequency oscillation verified to have high-frequency oscillatory components unattributable to a high-pass filtering effect. Ninety-five patients achieved successful seizure control, defined as International League against Epilepsy class 1 outcome. Multivariate logistic regression analysis demonstrated that complete resection of interictally-abnormal regions additively increased the chance of success. The model accuracy was further improved by incorporating z-score normalized high-frequency oscillation/modulation index or selective incorporation of verified high-frequency oscillation. The standard model had a classification accuracy of 0.75. Incorporation of normalized high-frequency oscillation/modulation index or verified high-frequency oscillation improved the classification accuracy up to 0.82. These outcome prediction models survived the cross-validation process and demonstrated an agreement between the model-based likelihood of success and the observed success on an individual basis. Interictal high-frequency oscillation and modulation index had a comparably additive utility in epilepsy presurgical evaluation. Our empirical data support the theoretical notion that the prediction of post-operative seizure outcomes can be optimized with the consideration of both interictal and ictal abnormalities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.