ArticleJAMA network open2021
Risk of Recall Among Medical Devices Undergoing US Food and Drug Administration 510(k) Clearance and Premarket Approval, 2008-2017.
Article in JAMA network open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 54 citations in OpenAlex.
- Medical Device Recalls in Neurosurgery: A United States Regulatory Analysis.Neurosurgery practice · 2026Review
- Cochlear Implant Complications and Outcomes: National Trends of the MAUDE Database From 2016 to 2024.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026Article
- Two decades of growth and trends in the FDA authorization of digital medical devices.NPJ digital medicine · 2026Article
- Metal-on-metal hip implants: Revisiting degradation product chemistry and molecular mechanisms of ARMD.Biomaterials and biosystems · 2026Review
- Clinical Evidence and FDA Recalls of Artificial Intelligence-Enabled Medical Devices.JAMA network open · 2026Article
- Risk of Recall Among Plastic Surgery Devices Cleared Through the FDA 510(k) Pathway.Aesthetic surgery journal. Open forum · 2026Article
- Early Recalls and Clinical Validation Gaps in Artificial Intelligence-Enabled Medical Devices.JAMA health forum · 2025Article
- Regulatory Insights From 27 Years of Artificial Intelligence/Machine Learning-Enabled Medical Device Recalls in the United States: Implications for Future Governance.JMIR medical informatics · 2025Article
- Recall of Orthopedic Implants Must Be Addressed.HSS journal : the musculoskeletal journal of Hospital for Special Surgery · 2025Article
- A Machine Learning Algorithm to Predict Medical Device Recall by the Food and Drug Administration.The western journal of emergency medicine · 2025Article
- Scoping review on regulation, implementation and postmarket surveillance of medical devices.PloS one · 2025Article
- Are Surgeons Going to Be Left Holding the Bag? Incisional Hernia Repair and Intra-Peritoneal Non-Absorbable Mesh Implant Complications.Journal of clinical medicine · 2024Review
- Energy-Based Medical Devices in Plastic Surgery: A Comparison of FDA-Approved Indications to Advertised Claims.Aesthetic surgery journal. Open forum · 2024Article
- The 510(k) Third Party Review Program: Promise and Potential.Journal of medical systems · 2023Review
- A Review on Electronic Health Record Text-Mining for Biomedical Name Entity Recognition in Healthcare Domain.Healthcare (Basel, Switzerland) · 2023Review
- Risk of Recall Associated With Modifications to High-risk Medical Devices Approved Through US Food and Drug Administration Supplements.JAMA network open · 2023Article
- Review of approvals and recalls of US specific medical devices in general and plastic surgery.Surgery in practice and science · 2023Article
- Article
- Article
- Characterization of US Food and Drug Administration Class I Recalls from 2018 to 2022 for Moderate- and High-Risk Medical Devices: A Cross-Sectional Study.Medical devices (Auckland, N.Z.) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: The US Food and Drug Administration (FDA) uses 510(k) clearance and premarket approval (PMA) pathways to ensure device safety before marketing. Premarket approval evaluates high-risk medical devices and requires clinical trials, whereas 510(k) clearance evaluates moderate-risk devices and relies on benchtop (nonclinical and biomechanical) and descriptive data. Existing literature suggests that the clinical trials required by PMA are associated with reduced risk of recall compared with devices granted 510(k) clearance. Several investigators have found weaknesses in pivotal PMA trials, raising safety concerns. Furthermore, methodological factors may have led to a previous underestimation of recall risk for devices with PMA. Objectives: To compare risk of recall and high-risk recall between devices that received 510(k) clearance and those that received PMA and to compare the risk of recall between devices for medical specialties. Design, Setting, and Participants: This cohort study compared devices with 510(k) clearance vs those with PMA that reached the market between January 1, 2008, and December 31, 2017. Two- to 12-year follow-up was obtained from the FDA's 510(k) and PMA medical device database. Orthopedic surgery was chosen arbitrarily as the reference category for analysis between specialties because no baseline exists. Statistical analysis was performed from February 1 to November 1, 2020. Main Outcomes and Measures: The FDA issues recalls for safety concerns. These recalls are stratified into class I, II, and III, with class I representing high-risk issues for serious harm or death. The main outcome was the hazard ratio of any recall and class I recall between devices with PMA and those with 510(k) clearance. The secondary outcome was the recall hazard ratio between specialties with respect to the reference category. A single Cox proportional hazards regression model evaluating the association of medical specialty and FDA approval pathway with the risk of recall was performed. Results: During the study period, 28 246 devices received 510(k) clearance and 310 devices (10.7%) received PMA; 3012 devices (10.7%) with 510(k) clearance and 84 devices (27.1%) with PMA were recalled. A total of 216 devices (0.8%) with 510(k) clearance and 16 devices (5.2%) with PMA had class I recalls. Devices with PMA compared with those with 510(k) clearance had a hazard ratio for recall of 2.74 (95% CI, 2.19-3.44; P < .001) and a hazard ratio for high-risk recall of 7.30 (95% CI, 4.39-12.13; P < .001). Only radiologic devices were associated with an increased risk of recall (hazard ratio, 1.57; 95% CI, 1.32-1.87; P < .001), whereas 6 specialties were assocated with a decreased risk compared with the orthopedic reference category: general and plastic surgery, otolaryngology, obstetrics and gynecology, physical medicine, hematology, and general hospital. Conclusions and Relevance: This study suggests that high-risk medical devices approved via PMA are associated with a greater risk of recall than previously reported. Most recalls are for devices with 510(k) clearance, also raising safety concerns. Strengthening postmarketing surveillance strategies and pivotal trials may improve device safety.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.