Evidence map›Paper›PMID 33952312›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2021

Native contrast visualization and tissue characterization of myocardial radiofrequency ablation and acetic acid chemoablation lesions at 0.55 T.

Aravindan Kolandaivelu, Chris G Bruce, Rajiv Ramasawmy, Dursun Korel Yildirim, Kendall J O'Brien, William H Schenke, Toby Rogers, Adrienne E Campbell-Washburn, Robert J Lederman, Daniel A Herzka

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.4field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Cardiac MRI at Low Field Strengths.Journal of magnetic resonance imaging : JMRI · 2024
    Review
  7. Article
  8. Interventional cardiovascular magnetic resonance: state-of-the-art.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Review
  9. Review
  10. Article
  11. Review
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Aravindan KolandaiveluCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
Chris G BruceCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
Rajiv RamasawmyCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
Dursun Korel YildirimCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
Kendall J O'BrienCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
William H SchenkeCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
Toby RogersCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
Adrienne E Campbell-WashburnCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
Robert J LedermanCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
Daniel A HerzkaCardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA. herzkad@nih.gov.ORCID 0000-0002-9400-7814
National Institutes of Health · USMedStar Washington Hospital Center · US

Funding

Novel catheter treatment of valve diseaseZIAHL006040 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2010 to 2025
$23.6M
Real-time MRI guided cardiovascular interventionZIAHL005062 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2009 to 2025
$21.6M
MRI catheter design and fabricationZIAHL006041 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2014 to 2025
$12.2M
Real-time cardiovascular MRI and co-registration technical developmentZIAHL006039 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2010 to 2024
$10.3M
Development of high-performance low field MRI technology ZIAHL006257 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI CAMPBELL-WASHBURN, ADRIENNE · 2021 to 2025
$8.1M
Therapies enabled-cardiovascular interventional MRIZ01HL005062 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2003 to 2008
$6.0M
Innovative Technology for MRI Guided ProceduresZIAHL006213 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI CAMPBELL-WASHBURN, ADRIENNE · 2016 to 2025
$5.4M
Intramural NIH HHS Z01 HL005062Intramural NIH HHS ZIA HL006213
6 · The paper itself

Abstract

purposeLow-field (0.55 T) high-performance cardiovascular magnetic resonance (CMR) is an attractive platform for CMR-guided intervention as device heating is reduced around 7.5-fold compared to 1.5 T. This work determines the feasibility of visualizing cardiac radiofrequency (RF) ablation lesions at low field CMR and explores a novel alternative method for targeted tissue destruction: acetic acid chemoablation.

methodsN = 10 swine underwent X-ray fluoroscopy-guided RF ablation (6-7 lesions) and acetic acid chemoablation (2-3 lesions) of the left ventricle. Animals were imaged at 0.55 T with native contrast 3D-navigator gated T1-weighted T1w) CMR for lesion visualization, gated single-shot imaging to determine potential for real-time visualization of lesion formation, and T1 mapping to measure change in T1 in response to ablation. Seven animals were euthanized on ablation day and hearts imaged ex vivo. The remaining animals were imaged again in vivo at 21 days post ablation to observe lesion evolution.

resultsChemoablation lesions could be visualized and displayed much higher contrast than necrotic RF ablation lesions with T1w imaging. On the day of ablation, in vivo myocardial T1 dropped by 19 ± 7% in RF ablation lesion cores, and by 40 ± 7% in chemoablation lesion cores (p < 4e-5). In high resolution ex vivo imaging, with reduced partial volume effects, lesion core T1 dropped by 18 ± 3% and 42 ± 6% for RF and chemoablation, respectively. Mean, median, and peak lesion signal-to-noise ratio (SNR) were all at least 75% higher with chemoablation. Lesion core to myocardium contrast-to-noise (CNR) was 3.8 × higher for chemoablation. Correlation between in vivo and ex vivo CMR and histology indicated that the periphery of RF ablation lesions do not exhibit changes in T1 while the entire extent of chemoablation exhibits T1 changes. Correlation of T1w enhancing lesion volumes indicated in vivo estimates of lesion volume are accurate for chemoablation but underestimate extent of necrosis for RF ablation.

conclusionThe visualization of coagulation necrosis from cardiac ablation is feasible using low-field high-performance CMR. Chemoablation produced a more pronounced change in lesion T1 than RF ablation, increasing SNR and CNR and thereby making it easier to visualize in both 3D navigator-gated and real-time CMR and more suitable for low-field imaging.

Indexed as

Catheter AblationRadiofrequency AblationAcetic AcidAnimalsMyocardiumPredictive Value of TestsSwineAcetic AcidArrhythmiasCatheter ablationChemoablationHeartImage-guided interventionMyocardial ablationRF ablationTissue characterization

Identifiers

PMID33952312
PMCPMC8101152
OpenAlexW3158979197

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.