ArticleJournal of applied clinical medical physics2021
Intrinsic detector sensitivity analysis as a tool to characterize ArcCHECK and EPID sensitivity to variations in delivery for lung SBRT VMAT plans.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 19 citations in OpenAlex.
- Complementary roles of GPU-accelerated Monte Carlo and ArcCHECK in TomoTherapy quality assurance.Physical and engineering sciences in medicine · 2026Article
- Efficacy and clinical use of novel high-resolution EPID-based 2D and 3D automated patient-specific quality assurance for SRS and SBRT patients.Radiation and environmental biophysics · 2026Article
- Classification performances of two diode arrays for patient-specific quality assurance of stereotactic body radiation therapy treatments based on absolute dose measurements in phantom.Journal of applied clinical medical physics · 2025Article
- A Beam Orientation Quality Assurance Framework for Gyroscopic Stereotactic Radiosurgery Systems.Cureus · 2025Article
- Dosimetric impact of MLC positional errors on dose distribution in IMRT.Journal of applied clinical medical physics · 2024Article
- Application of error classification model using indices based on dose distribution for characteristics evaluation of multileaf collimator position errors.Scientific reports · 2023Article
- [Study on the sensitivity of a volumetric modulated arc therapy plan verification equipment on multi-leaf collimator opening and closing errors and its gamma pass rate limit].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023Article
- Comprehensive clinical evaluation of TomoEQA for patient-specific pre-treatment quality assurance in helical tomotherapy.Radiation oncology (London, England) · 2022Article
- Evaluation of the ability of three commercially available dosimeters to detect systematic delivery errors in step-and-shoot IMRT plans.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2021Article
- Evaluating Mobius3D Dose Calculation Accuracy for Small-Field Flattening- Filter-Free Photon Beams.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo investigate intrinsic sensitivity of an electronic portal imaging device (EPID) and the ArcCHECK detector and to use this in assessing their performance in detecting delivery variations for lung SBRT VMAT. The effect of detector spatial resolution and dose matrix interpolation on the gamma pass rate was also considered. MATERIALS AND
methodsFifteen patients' lung SBRT VMAT plans were used. Delivery variations (errors) were introduced by modifying collimator angles, multi-leaf collimator (MLC) field sizes and MLC field shifts by ±5, ±2, and ±1 degrees or mm (investigating 103 plans in total). EPID and ArcCHECK measured signals with introduced variations were compared to measured signals without variations (baseline), using OmniPro-I'mRT software and gamma criteria of 3%/3 mm, 2%/2 mm, 2%/1 mm, and 1%/1 mm, to test each system's basic performance. The measurement sampling resolution for each was also changed to 1 mm and results compared to those with the default detector system resolution.
resultsIntrinsic detector sensitivity analysis, that is, comparing measurement to baseline measurement, rather than measurement to plan, demonstrated the intrinsic constraints of each detector and indicated the limiting performance that users might expect. Changes in the gamma pass rates for ArcCHECK, for a given introduced error, were affected only by dose difference (DD %) criteria. However, the EPID showed only slight changes when changing DD%, but greater effects when changing distance-to-agreement criteria. This is pertinent for lung SBRT where the minimum dose to the target will drop dramatically with geometric errors. Detector resolution and dose matrix interpolation have an impact on the gamma results for these SBRT plans and can lead to false positives or negatives in error detection if not understood.
conclusionThe intrinsic sensitivity approach may help in the selection of more meaningful gamma criteria and the choice of optimal QA device for site-specific dose verification.