ArticleAnnals of intensive care2021
Transcranial sonographic assessment of the third ventricle in neuro-ICU patients to detect hydrocephalus: a diagnostic reliability pilot study.
Article in Annals of intensive care, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02830269 (Third Ventricle Echographic Study for Neuro-intensive Care Unit Patients), which is not on this map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Third Ventricle Echographic Study for Neuro-intensive Care Unit Patients
Who cites it
9 citing papers in PubMed, 17 citations in OpenAlex.
- Paediatric and adult neurological point-of-care ultrasound: Review of the evidence, and the UK accreditation pathway.Journal of the Intensive Care Society · 2026Article
- Ultrasound Assessment of the Third Ventricle Diameter: Agreement With CT Results in the Pediatric Population.Critical care explorations · 2026Observational
- Stroke-point-of-care ultrasound: a new holistic approach to bedside evaluation in stroke patients using ultrasound.European stroke journal · 2026Review
- Brain Point-of-Care Ultrasound (BrainPOCUS) in Adult Critical Care: An Introduction to Methods.Cureus · 2025Article
- Portable Bedside Low-Field MRI for Assessment of Ventricular Size.AJNR. American journal of neuroradiology · 2025Article
- The Role of Transcranial Ultrasound Imaging in Intensive Care Treatment of Decompressive Hemicraniectomy Patients: A Retrospective Single-Center Analysis.Journal of clinical medicine · 2024Article
- Ultrasound-guided initial diagnosis and follow-up of pediatric idiopathic intracranial hypertension.Pediatric radiology · 2024Article
- Transcranial sonography: practical use in the intensive care unit.Anaesthesiology intensive therapy · 2024Review
- Pupillometry in the follow-up of patients undergoing EVT - prediction of space-occupying hemispheric infarction.Journal of neurology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTranscranial sonography is a point-of-care tool recommended in intensive care units (ICU) to monitor brain injured patients. Objectives of the study was to assess feasibility and reliability of the third ventricle (V3) diameter measurement using transcranial sonography (TCS) compared to brain computed-tomography (CT), the gold standard measurement, and to measure the TCS learning curve.
designprospective study, in a 16-bed neurological ICU in an academic hospital. Every consecutive brain injured adult patient, who required a brain CT and TCS monitoring were included. The V3 diameter was blindly measured by TCS and CT. Intraclass correlation coefficient (ICC) and Bland-Altman plot were used to assess the reliability and agreement between TCS and CT V3 measurements. Diagnosis performance of the V3 diameter using TCS to detect hydrocephalus was measured. Absolute difference between V3 measurement by residents and experts was measured consecutively to assess the learning curve.
resultsAmong the 100 patients included in the study, V3 diameter could be assessed in 87 patients (87%) from at least one side of the skull. Both temporal windows were available in 70 patients (70%). The ICC between V3 diameter measured by TCS and CT was 0.90 [95% CI 0.84-0.93] on the right side, and 0.92 [0.88-0.95] on the left side. In Bland-Altman analysis, mean difference, standard deviation, 95% limits of agreement were 0.36, 1.52, - 2.7 to 3.3 mm, respectively, on the right side; 0.25, 1.47, - 2.7 to 3.1 mm, respectively, on the left side. Among the 35 patients with hydrocephalus, V3 diameters could be measured by TCS in 31 patients (89%) from at least one side. Hydrocephalus was, respectively, excluded, confirmed, or inconclusive using TCS in 35 (40%), 25 (29%) and 27 (31%) of the 87 assessable patients. After 5 measurements, every resident reached a satisfactory measurement compared to the expert operator.
conclusionTCS allows rapid, simple and reliable V3 diameter measurement compared with the gold standard in neuro-ICU patients. Aside from sparing irradiating procedures and transfers to the radiology department, it may especially increase close patient monitoring to detect clinically occult hydrocephalus earlier. Further studies are needed to measure the potential clinical benefit of this method.
trial registrationClinicalTrials.gov ID: NCT02830269.