ReviewDer Orthopade2021
[Polymethyl methacrylate cement coating of intramedullary implants : A new technique for revision surgery with the example of a temporary knee arthrodesis. Video article].
Review in Der Orthopade, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 citations in OpenAlex.
- Treatment of Periprosthetic Joint Infection and Fracture-Related Infection With a Temporary Arthrodesis Made by PMMA-Coated Intramedullary Nails - Evaluation of Technique and Quality of Life in Implant-Free Interval.Frontiers in surgery · 2022Article
- [Fracture-related infections after intramedullary nailing : Diagnostics and treatment].Der Unfallchirurg · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe coating of intramedullary rods with polymethyl methacrylate (PMMA) bone cement containing antibiotics ensures a high concentration of antibiotics locally and stability in fractures that are not yet consolidated. However, bone cement can detach when the implant is removed and remain in the medullary cavity of the long bones. CASE REPORT: After a periprosthetic knee infection, a 56-year-old patient suffered from a painful reinfection of Staphylococcus epidermidis. This was an indication for removal of the prosthesis. OPERATION: After soft-tissue debridement and synovectomy, rotating hinge prosthesis that had been inserted was removed. Humeral nails coated with PMMA cement containing antibiotics were used as temporary intramedullary implants. To prevent the bone cement from detaching when the implant was removed and cement residue from remaining in the bone, the humeral nails were reinforced with cerclage wire. The coated implant was then press fit into the medullary cavity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.