Evidence map›Paper›PMID 33942138›Full record

ArticleEuropean radiology2021

Automatic prediction of left cardiac chamber enlargement from chest radiographs using convolutional neural network.

Ju Gang Nam, Jinwook Kim, Keonwoo Noh, Hyewon Choi, Da Som Kim, Seung-Jin Yoo, Hyun-Lim Yang, Eui Jin Hwang, Jin Mo Goo, Eun-Ah Park and 3 more

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 6 institutions in 2 countries.

Ju Gang Nam *Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
Jinwook Kim *Information and Communication Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu, 42988, Republic of Korea.
Keonwoo NohInformation and Communication Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu, 42988, Republic of Korea.
Hyewon ChoiRadiology, Seoul National University Hospital, Seoul, Republic of Korea.
Da Som KimRadiology, Busan Paik Hospital and Inje University College of Medicine, Busan, 47392, Republic of Korea.
Seung-Jin YooRadiology, Hanyang University Medical Center and College of Medicine, Seoul, 04763, Republic of Korea.
Hyun-Lim YangInformation and Communication Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu, 42988, Republic of Korea.
Eui Jin HwangRadiology, Seoul National University Hospital, Seoul, Republic of Korea.
Jin Mo GooRadiology, Seoul National University Hospital, Seoul, Republic of Korea.
Eun-Ah ParkRadiology, Seoul National University Hospital, Seoul, Republic of Korea.
Hye Young SunRadiology, Seoul National University Hospital Healthcare System Gangnam Center, Seoul, 06236, Republic of Korea.
Min-Soo KimSchool of Computing, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea.
Chang Min ParkRadiology, Seoul National University Hospital, Seoul, Republic of Korea. cmpark.morphius@gmail.com.ORCID http://orcid.org/0000-0003-1884-3738
Seoul National University · KRDaegu Gyeongbuk Institute of Science and Technology · KRHanyang University Medical Center · KRInje University Busan Paik Hospital · KRKorea Advanced Institute of Science and Technology · KRSeoul National University Hospital · KR

Funding

National Research Foundation of Korea (NRF) grant funded by the Ministry of Science and ICT (MSIT) NRF-2018R1A5A1060031Seoul National University Hospital Research Fund 03-2019-0190
6 · The paper itself

Abstract

objectiveTo develop deep learning-based cardiac chamber enlargement-detection algorithms for left atrial (DLCE-LAE) and ventricular enlargement (DLCE-LVE), on chest radiographs

methodsFor training and internal validation of DLCE-LAE and -LVE, 5,045 chest radiographs (CRs; 2,463 normal and 2,393 LAE) and 1,012 CRs (456 normal and 456 LVE) matched with the same-day echocardiography were collected, respectively. External validation was performed using 107 temporally independent CRs. Reader performance test was conducted using the external validation dataset by five cardiothoracic radiologists without and with the results of DLCE. Classification performance of DLCE was evaluated and compared with those of the readers and conventional radiographic features, including cardiothoracic ratio, carinal angle, and double contour. In addition, DLCE-LAE was tested on 5,277 CRs from a healthcare screening program cohort.

resultsDLCE-LAE showed areas under the receiver operating characteristics curve (AUROCs) of 0.858 on external validation. On reader performance test, DLCE-LAE showed better results than pooled radiologists (AUROC 0.858 vs. 0.651; p < .001) and significantly increased their performance when used as a second reader (AUROC 0.651 vs. 0.722; p < .001). DLCE-LAE also showed a significantly higher AUROC than conventional radiographic findings (AUROC 0.858 vs. 0.535-0.706; all ps < .01). In the healthcare screening cohort, DLCE-LAE successfully detected 71.0% (142/200) CRs with moderate-to-severe LAE (93.5% [29/31] of severe cases), while yielding 11.8% (492/4,184) false-positive rate. DLCE-LVE showed AUROCs of 0.966 and 0.594 on internal and external validation, respectively.

conclusionDLCE-LAE outperformed and improved cardiothoracic radiologists' performance in detecting LAE and showed promise in screening individuals with moderate-to-severe LAE in a healthcare screening cohort. KEY POINTS: • Our deep learning algorithm outperformed cardiothoracic radiologists in detecting left atrial enlargement on chest radiographs. • Cardiothoracic radiologists improved their performance in detecting left atrial enlargement when aided by the algorithm. • On a healthcare-screening cohort, our algorithm detected 71.0% (142/200) radiographs with moderate-to-severe left atrial enlargement while yielding 11.8% (492/4,184) false-positive rate.

Indexed as

Deep LearningRadiography, ThoracicAlgorithmsHumansNeural Networks, ComputerRadiographyDiagnosis, computer-assistedLeft atriumX-ray film

Identifiers

PMID33942138
OpenAlexW3157826233

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.