Automatic ultrasound scanning robotic system with optical waveguide-based force measurement.

Shihang Chen, Zhaojun Li, Yanping Lin, Fang Wang, Qixin Cao

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shihang ChenSchool of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
Zhaojun LiShanghai General Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
Yanping LinSchool of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China. yanping_lin@sjtu.edu.cn.
Fang WangShanghai General Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
Qixin CaoSchool of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China.

Funding

National Natural Science Foundation of China 51575343
6 · The paper itself

Abstract

purposeThe three-dimensional (3D) ultrasound (US) imaging realized by continuous scanning of a region is of great value for medical diagnosis and robot-assisted needle insertion. During scanning, the contact force and posture between the probe and skin of the patient are crucial factors that determine the quality of US imaging. We propose a robotic system for automatic scanning of curved surfaces with a stable contact force and vertical contact posture (the probe is parallel to the normal of the surface at the contact point).

methodsA 6-DOF robotic arm is used to hold and drive a two-dimensional (2D) US probe to complete automatic scanning. Further, a path-planning strategy is proposed to generate the scan path covering the selected area automatically. We also developed a novel force-measuring device based on optical waveguides to measure the distributed contact force and contact posture. Based on the measured force and posture, the robotic arm automatically adjusts the position and orientation of the probe and maintains a stable contact force and vertical contact posture at each scan point.

resultsThe novel force-measuring device is easy to fabricate, integrates with the probe and has the capacity of measuring the force distributed on the contact surface and estimating the contact posture. The experimental results of automatic scanning of a US phantom and parts of the human body demonstrate that the proposed system performs well in automatically scanning curved surfaces, maintaining a stable contact force and vertical contact posture and producing a good quality 3D US volume.

conclusionAn automatic US scanning robotic system with an optical waveguide-based force-measuring device was developed and tested successfully. Experimental results demonstrated the feasibility of the proposed system to scan the human body.

Indexed as

Phantoms, ImagingEquipment DesignHumansImaging, Three-DimensionalRobotic Surgical ProceduresUltrasonographyContact force measurementOptical waveguideRobotic assistanceStable contact forceUltrasound scanning

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.