Evidence map›Paper›PMID 33938608›Full record

SynthesisJournal of applied clinical medical physics2021

The application of metal artifact reduction methods on computed tomography scans for radiotherapy applications: A literature review.

Sathyathas Puvanasunthararajah, Davide Fontanarosa, Marie-Luise Wille, Saskia M Camps

Open access · goldAbstract readSystematic Review
In one paragraph

Synthesis in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed, 1 pooled it
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed, 1 synthesis or guideline pooled it, 50 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Patient selection, ventricular tachycardia substrate delineation, and data transfer for stereotactic arrhythmia radioablation: a clinical consensus statement of the European Heart Rhythm Association of the European Society of Cardiology and the Heart Rhythm Society.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. A robust index for metal artifact quantification in computed tomography.Journal of applied clinical medical physics · 2024
    Article
  16. Review
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Sathyathas PuvanasunthararajahSchool of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia.
Davide FontanarosaSchool of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia.
Marie-Luise WilleCentre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia.
Saskia M CampsEBAMed SA, Geneva, Switzerland.
Queensland University of Technology · AUADMED (Switzerland) · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Metal artifact reduction (MAR) methods are used to reduce artifacts from metals or metal components in computed tomography (CT). In radiotherapy (RT), CT is the most used imaging modality for planning, whose quality is often affected by metal artifacts. The aim of this study is to systematically review the impact of MAR methods on CT Hounsfield Unit values, contouring of regions of interest, and dose calculation for RT applications. This systematic review is performed in accordance with the PRISMA guidelines; the PubMed and Web of Science databases were searched using the main keywords "metal artifact reduction", "computed tomography" and "radiotherapy". A total of 382 publications were identified, of which 40 (including one review article) met the inclusion criteria and were included in this review. The selected publications (except for the review article) were grouped into two main categories: commercial MAR methods and research-based MAR methods. Conclusion: The application of MAR methods on CT scans can improve treatment planning quality in RT. However, none of the investigated or proposed MAR methods was completely satisfactory for RT applications because of limitations such as the introduction of other errors (e.g., other artifacts) or image quality degradation (e.g., blurring), and further research is still necessary to overcome these challenges.

Indexed as

ArtifactsTomography, X-Ray ComputedAlgorithmsHumansMetalsPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedMetalscomputed tomographymetal artifact reductionmetal artifactsradiotherapy

Identifiers

PMID33938608
PMCPMC8200502
OpenAlexW3158753625

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.