Development of an L-band resonator optimized for fast scan EPR imaging of the mouse head.

Alexandre Samouilov, Denis Komarov, Sergey Petryakov, Arkadiy Iosilevich, Jay L Zweier

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.7field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Rapid scan EPR: Automated digital resonator control for low-latency data acquisition.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2022
    Article
  3. High fidelity triangular sweep of the magnetic field for millisecond scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Alexandre SamouilovDavis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, Ohio, USA.ORCID 0000-0002-0868-7252
Denis KomarovDavis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, Ohio, USA.
Sergey PetryakovDavis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, Ohio, USA.
Arkadiy IosilevichDavis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, Ohio, USA.
Jay L ZweierDavis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, Ohio, USA.
The Ohio State University · US

Funding

Role of Cytoglobin in the Regulation of Vascular ToneR01HL131941 · NHLBI · OHIO STATE UNIVERSITY · PI JAY Louis ZWEIER · 2017 to 2026
$5.7M
Mechanisms of Nicotine Inhalation-Induced Cardiovascular DiseaseR01HL135648 · NHLBI · OHIO STATE UNIVERSITY · PI ZWEIER, JAY LOUIS · 2017 to 2021
$2.6M
Integration of High Field MRI and EPRI For Functional ImagingR01EB016096 · NIBIB · OHIO STATE UNIVERSITY · PI ZWEIER, JAY LOUIS · 2013 to 2016
$2.3M
NHLBI NIH HHS R01 HL131941NHLBI NIH HHS R01 HL135648NIBIB NIH HHS R01 EB016096
6 · The paper itself

Abstract

purposeTo develop a novel resonator for high-quality fast scan electron paramagnetic resonance (EPR) and EPR/NMR co-imaging of the head and brain of mice at 1.25 GHz.

methodsResonator dimensions were scaled to fit the mouse head with maximum filling factor. A single-loop 6-gap resonator of 20 mm diameter and 20 mm length was constructed. High resonator stability was achieved utilizing a fixed position double coupling loop. Symmetrical mutually inverted connections rendered it insensitive to field modulation and fast scan. Coupling adjustment was provided by a parallel-connected variable capacitor located at the feeding line at λ/4 distance. To minimize radiation loss, the shield around the resonator was supplemented with a planar conductive disc that focuses return magnetic flux.

resultsCoupling of the resonator loaded with the mouse head was efficient and easy. This resonator enabled high-quality in vivo 3D EPR imaging of the mouse head following intravenous infusion of nitroxide probes. With this resonator and rapid scan EPR system, 4 ms scans were acquired in forward and reverse directions so that images with 2-scan 3,136 projections were acquired in 25 s. Head images were achieved with resolutions of 0.4 mm, enabling visualization of probe localization and uptake across the blood-brain barrier.

conclusionsThis resonator design provides good sensitivity, high stability, and B

Indexed as

Magnetic Resonance ImagingAnimalsElectron Spin Resonance SpectroscopyMicePhantoms, ImagingRadionuclide Imagingelectron paramagnetic resonance imaginginstrument developmentmicrowave resonatormouse head imagingparamagnetic probes

Identifiers

PMID33938574
PMCPMC8295191
OpenAlexW3157651646

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.