ArticleBulletin of emergency and trauma2021
The Comparison of Biomechanical Volar and Dorsal Plating in Distal Part Radius Fractures; a Finite Element Analysis Study.
Article in Bulletin of emergency and trauma, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Evaluating the biomechanical performance of Ti6Al4V volar plates in patients with distal radius fractures.Frontiers in bioengineering and biotechnology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo compare the stability of the radius stabilized fractured parts by volar and dorsal planting based on modeling approach.
methodsTen forearm models were created based on Computed Tomography (CT) Scan images by using of Mimics software. The distal part fracture of radius was induced in the models. The stress were developed and implanted in various parts of the bone and and their displacement were evaluated in volar and dorsal inserted implants.
resultsThe results of this study showed that the stress developed in screws, implant and bony parts differed significantly between volar and dorsal plate conditions. The displacement of implant and bony parts in volar plating was more than dorsal plating (
conclusionThe stress developed in dorsal and volar implants is not too high to fail the structure. However, it seems that the irritation of soft tissue and tendon would be less in volar inserted implant than dorsal implant. It is recommended to use valor plating to be a good approach for stabilizing the distal part fracture of radius.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.