Evidence map›Paper›PMID 33937025›Full record

ArticleFrontiers in oncology2021

On the Importance of Individualized, Non-Coplanar Beam Configurations in Mediastinal Lymphoma Radiotherapy, Optimized With Automated Planning.

Linda Rossi, Patricia Cambraia Lopes, Joana Marques Leitão, Cecile Janus, Marjan van de Pol, Sebastiaan Breedveld, Joan Penninkhof, Ben J M Heijmen

Abstract read
In one paragraph

Article in Frontiers in oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Lung SBRT: Dose gradient optimization based on target size.Medical dosimetry : official journal of the American Association of Medical Dosimetrists
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Linda RossiDepartment of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands.
Patricia Cambraia LopesDepartment of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands.
Joana Marques LeitãoDepartment of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands.
Cecile JanusDepartment of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands.
Marjan van de PolDepartment of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands.
Sebastiaan BreedveldDepartment of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands.
Joan PenninkhofDepartment of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands.
Ben J M HeijmenDepartment of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeLiterature is non-conclusive regarding selection of beam configurations in radiotherapy for mediastinal lymphoma (ML) radiotherapy, and published studies are based on manual planning with its inherent limitations. In this study, coplanar and non-coplanar beam configurations were systematically compared, using a large number of automatically generated plans. MATERIAL AND

methodsAn autoplanning workflow, including beam configuration optimization, was configured for young female ML patients. For each of 25 patients, 24 plans with different beam configurations were generated with autoplanning: 11 coplanar CP_x plans and 11 non-coplanar NCP_x plans with x = 5 to 15 IMRT beams with computer-optimized, patient-specific configurations, and the coplanar VMAT and non-coplanar Butterfly VMAT (B-VMAT) beam angle class solutions (600 plans in total).

resultsAutoplans compared favorably with manually generated, clinically delivered plans, ensuring that beam configuration comparisons were performed with high quality plans. There was no beam configuration approach that was best for all patients and all plan parameters. Overall there was a clear tendency towards higher plan quality with non-coplanar configurations (NCP_x≥12 and B-VMAT). NCP_x≥12 produced highly conformal plans with on average reduced high doses in lungs and patient and also a reduced heart Dmean, while B-VMAT resulted in reduced low-dose spread in lungs and left breast.

conclusionsNon-coplanar beam configurations were favorable for young female mediastinal lymphoma patients, with patient-specific and plan-parameter-dependent dosimetric advantages of NCP_x≥12 and B-VMAT. Individualization of beam configuration approach, considering also the faster delivery of B-VMAT vs. NCP_x≥12, can importantly improve the treatments.

Indexed as

automated multi-criterial planning (MCO)comparisonindividualized beam angle optimizationmediastinal lymphomanon-coplanar anglenumber of beamspersonalized radiotherapyVMAT versus IMRT

Identifiers

PMID33937025
PMCPMC8082440

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.