ArticleQuantitative imaging in medicine and surgery2021
Research on obtaining pseudo CT images based on stacked generative adversarial network.
Article in Quantitative imaging in medicine and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 11 citations in OpenAlex.
- Ultrasound-Based Tomographic Imaging Reconstruction and Synthesis Methods: a Scoping Review.Journal of imaging informatics in medicine · 2026Article
- Influence of high-performance image-to-image translation networks on clinical visual assessment and outcome prediction: utilizing ultrasound to MRI translation in prostate cancer.International journal of computer assisted radiology and surgery · 2026Article
- Clinical validation of enhanced CT imaging for distal radius fractures through conditional Generative Adversarial Networks (cGAN).PloS one · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo investigate the feasibility of using a stacked generative adversarial network (sGAN) to synthesize pseudo computed tomography (CT) images based on ultrasound (US) images.
methodsThe pre-radiotherapy US and CT images of 75 patients with cervical cancer were selected for the training set of pseudo-image synthesis. In the first stage, labeled US images were used as the first conditional GAN input to obtain low-resolution pseudo CT images, and in the second stage, a super-resolution reconstruction GAN was used. The pseudo CT image obtained in the first stage was used as an input, following which a high-resolution pseudo CT image with clear texture and accurate grayscale information was obtained. Five cross validation tests were performed to verify our model. The mean absolute error (MAE) was used to compare each pseudo CT with the same patient's real CT image. Also, another 10 cases of patients with cervical cancer, before radiotherapy, were selected for testing, and the pseudo CT image obtained using the neural style transfer (NSF) and CycleGAN methods were compared with that obtained using the sGAN method proposed in this study. Finally, the dosimetric accuracy of pseudo CT images was verified by phantom experiments.
resultsThe MAE metric values between the pseudo CT obtained based on sGAN, and the real CT in five-fold cross validation are 66.82±1.59 HU, 66.36±1.85 HU, 67.26±2.37 HU, 66.34±1.75 HU, and 67.22±1.30 HU, respectively. The results of the metrics, namely, normalized mutual information (NMI), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR), between the pseudo CT images obtained using the sGAN method and the ground truth CT (CTgt) images were compared with those of the other two methods via the paired t-test, and the differences were statistically significant. The dice similarity coefficient (DSC) measurement results showed that the pseudo CT images obtained using the sGAN method were more similar to the CTgt images of organs at risk. The dosimetric phantom experiments also showed that the dose distribution between the pseudo CT images synthesized by the new method was similar to that of the CTgt images.
conclusionsCompared with NSF and CycleGAN methods, the sGAN method can obtain more accurate pseudo CT images, thereby providing a new method for image guidance in radiotherapy for cervical cancer.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.