ArticleJournal of clinical orthopaedics and trauma2021
Outcomes and complications after dual plate vs. single plate fixation of displaced mid-shaft clavicle fractures: A systematic review and meta-analysis.
Article in Journal of clinical orthopaedics and trauma, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Dual-plating is associated with lower implant removal rates compared with single-plate fixation for midshaft clavicle fractures: a meta-analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Pooled it
- Practice patterns in indications, timing, and imaging for clavicle hardware removal: a survey among German-speaking shoulder surgeons.BMC musculoskeletal disorders · 2026Article
- Review
- Primary stability of nailing versus low-profile dual plating of mid-clavicular fractures- a biomechanical cadaveric study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025Article
- Augmentation of clavicular fractures by dual plating.International journal of burns and trauma · 2025Article
- Dual mini-plate vs. T-plate fixation for Edinburgh type IB proximal clavicle fractures: a comparative clinical study.American journal of translational research · 2025Article
- Dual plate has better biomechanical stability than hook plate or superior single plate for the fixation of unstable distal clavicle fractures: a finite element analysis.Archives of orthopaedic and trauma surgery · 2023Article
- Clinical Outcomes of Double Mini-Plating Compared with a Single Superior Plating in Midshaft Clavicular Fractures: A Randomized Clinical Trial Study.Advanced biomedical research · 2023Article
- Biomechanical Evaluation of Different Plate Configurations for Midshaft Clavicle Fracture Fixation: Single Plating Compared with Dual Mini-Fragment Plating.JB & JS open accessArticle
Corrections and comments
- Erratum issued
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionOpen reduction and internal fixation (ORIF) of displaced midshaft clavicle fractures is associated with higher union rates and earlier functional recovery. However, ORIF with plate fixation is associated with complications including implant irritation and implant failure. Dual plate fixation provides fixation in orthogonal planes, and uses a lower profile fixation technique in comparison to pre-contoured and surgeon-contoured small-fragment locking plates, which may be more prominent. The objective of this study was to conduct a systematic review to summarize outcomes and complications associated with surgical fixation of displaced acute midshaft clavicle fractures with dual plate fixation.
methodsUsing a predetermined study protocol in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines, the databases MEDLINE, EMBASE, and CENTRAL were searched from inception to 2020 to identify studies reporting outcomes in acute midshaft clavicle fractures treated with dual plate fixation. All clinical studies which reported on outcomes of dual plating in patients with acute midshaft clavicle fractures were included. Baseline demographics, plate fixation constructs, fracture union rates, implant removal rates, maintenance of reduction, symptomatic implant rates, wound complications, and functional outcomes were extracted. All extracted data were recorded, and descriptive statistics were summarized. Meta-analysis was performed on fracture union rates and implant removal rates using random-effects modeling using Mantel-Haenszel weighting.
resultsOur literature search identified 2226 unique abstracts, of which eight studies met our study inclusion criteria following review. A total of 278 patients made up of 79.8% male with an average age of 36.0 years were included. The overall dual plate implant removal rate was 4.2% with excellent rates of union reported. Moreover, single plate fixation was associated with a 3.9-fold increased implant removal rate compared to dual plate fixation.
conclusionResults from this systematic review demonstrate that ORIF of displaced midshaft clavicle fractures using a dual plate fixation technique is a viable option to reduce the incidence of implant removal, without negatively impacting the rate of fracture union. LEVEL OF EVIDENCE: Therapeutic Level III.