Evidence map›Paper›PMID 33934266›Full record

ArticleDaru : journal of Faculty of Pharmacy, Tehran University of Medical Sciences2021

RP-HPLC method validation for fast extraction and quantification of Levonorgestrel drug from silicone based intrauterine device intended for in-process and finished formulation.

Midhu George Veeran, Karthikeyan C, Bharaniraja B, Diksha Painuly, Abi Santhosh Aprem

Open access · greenAbstract readValidation Study
In one paragraph

Article in Daru : journal of Faculty of Pharmacy, Tehran University of Medical Sciences, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Midhu George VeeranCorporate Research and Development Centre, HLL Lifecare Limited, Akkulam, Sreekariyam, Trivandrum, Kerala, 695017, India.
Karthikeyan CCorporate Research and Development Centre, HLL Lifecare Limited, Akkulam, Sreekariyam, Trivandrum, Kerala, 695017, India.
Bharaniraja BCorporate Research and Development Centre, HLL Lifecare Limited, Akkulam, Sreekariyam, Trivandrum, Kerala, 695017, India.
Diksha PainulyCorporate Research and Development Centre, HLL Lifecare Limited, Akkulam, Sreekariyam, Trivandrum, Kerala, 695017, India. dikshapainuly@lifecarehll.com.ORCID http://orcid.org/0000-0003-0244-7255
Abi Santhosh ApremCorporate Research and Development Centre, HLL Lifecare Limited, Akkulam, Sreekariyam, Trivandrum, Kerala, 695017, India.
HLL Lifecare (India) · IN

Funding

HLL Lifecare Ltd. India 16/05
6 · The paper itself

Abstract

backgroundTo develop and validate a simple and consistent reversed phase high performance liquid chromatography (RP-HPLC) method for the estimation of Levonorgestrel (LNG) drug from silicone based intrauterine device.

methodsSample solution was prepared using tetrahydrofuran (THF) as solvent for the drug extraction, and RP-HPLC analysis was performed using Luna C18 analytical column (150 × 4.6 mm, 5 μm, 100 Å - Phenomenex), with a mobile phase consisting of a mixture of acetonitrile and water (50:50, v/v) at a flow rate of 1.0 ml/min and injection volume of 20 μl. Detection was carried out at 241 nm in PDA detector, with a total run time of 15 min. The method was validated in accordance with ICH guidelines. Method applicability was tested for optimizing formulation using quality-by-design approach, to check the stability and content uniformity of levonorgestrel-silicone mixture (core blend), and quantifying the amount of LNG from commercially available silicone based formulation.

resultsThe retention time for LNG drug was obtained at 8.5 min (± 0.3 min). A linear relationship was observed over the concentration range of 2.6-15.6 μg/ml with the correlation coefficient (r) value 0.9999. The method was found to be precise within the acceptable limit (RSD < 2%) and the drug recovery from the intrauterine device was found in the range 99.78-100.0%. Content uniformity for different prototypes developed was observed in the range of 91.6-101.4%, and assay of optimized core blend was in the range of 97.78-106.79% during the 10 days of retention period for stability studies.

conclusionThe validated method is found to be a simple, accurate, precise, reproducible, and hence can be used for the routine analysis of LNG such as in-process, quality control and stability assays of silicone based intrauterine devices by RP-HPLC.

Indexed as

Intrauterine DevicesChromatography, High Pressure LiquidChromatography, Reverse-PhaseContraceptive Agents, FemaleLevonorgestrelReproducibility of ResultsSiliconesContraceptive Agents, FemaleLevonorgestrelSiliconesIntrauterine deviceLevonorgestrelQuality by design (QbD)SiliconeValidation

Identifiers

PMID33934266
PMCPMC8149566
OpenAlexW3157657654

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.