In one paragraph

Article in Heart rhythm, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.4field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 1 country.

Michele OriniElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom; Institute of Cardiovascular Science, University College London, London, United Kingdom.
Peter TaggartInstitute of Cardiovascular Science, University College London, London, United Kingdom. Electronic address: p.taggart@ucl.ac.uk.
Anish BhuvaElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom; Institute of Cardiovascular Science, University College London, London, United Kingdom.
Neil RobertsElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom.
Carmelo Di SalvoElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom.
Martin YatesElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom.
Sveeta BadianiElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom.
Stefan Van DuijvenbodenInstitute of Cardiovascular Science, University College London, London, United Kingdom.
Guy LloydElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom.
Andrew SmithElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom.
Pier D LambiaseElectrophysiology Department, Barts Heart Centre at St. Bartholomew's Hospital, London, United Kingdom; Institute of Cardiovascular Science, University College London, London, United Kingdom.
St Bartholomew's Hospital · GBThe London College · GBUniversity College London · GB

Funding

Medical Research Council G0901819
6 · The paper itself

Abstract

backgroundInhomogeneity of ventricular contraction is associated with sudden cardiac death, but the underlying mechanisms are unclear. Alterations in cardiac contraction impact electrophysiological parameters through mechanoelectric feedback. This has been shown to promote arrhythmias in experimental studies, but its effect in the in vivo human heart is unclear.

objectiveThe purpose of this study was to quantify the impact of regional myocardial deformation provoked by a sudden increase in ventricular loading (aortic occlusion) on human cardiac electrophysiology.

methodsIn 10 patients undergoing open heart cardiac surgery, left ventricular (LV) afterload was modified by transient aortic occlusion. Simultaneous assessment of whole-heart electrophysiology and LV deformation was performed using an epicardial sock (240 electrodes) and speckle-tracking transesophageal echocardiography. Parameters were matched to 6 American Heart Association LV model segments. The association between changes in regional myocardial segment length and activation-recovery interval (ARI; a conventional surrogate for action potential duration) was studied using mixed-effect models.

resultsIncreased ventricular loading reduced longitudinal shortening (P = .01) and shortened ARI (P = .02), but changes were heterogeneous between cardiac segments. Increased regional longitudinal shortening was associated with ARI shortening (effect size 0.20 [0.01-0.38] ms/%; P = .04) and increased local ARI dispersion (effect size -0.13 [-0.23 to -0.03] ms/%; P = .04). At the whole organ level, increased mechanical dispersion translated into increased dispersion of repolarization (correlation coefficient r = 0.81; P = .01).

conclusionMechanoelectric feedback can establish a potentially proarrhythmic substrate in the human heart and should be considered to advance our understanding and prevention of cardiac arrhythmias.

Indexed as

ElectrocardiographyFeedbackAgedArrhythmias, CardiacEchocardiographyFemaleHeart Conduction SystemHeart VentriclesHumansMaleMiddle AgedMyocardial ContractionArrhythmiaCardiac strainElectromechanical couplingMechanoelectric feedbackRepolarization

Identifiers

PMID33932588
PMCPMC8353585
OpenAlexW3159746454

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.