Evidence map›Paper›PMID 33932129›Full record

ArticleESC heart failure2021

Five-year survival and use of hospital services following ICD and CRT implantation: comparing real-world data with RCTs.

Alex Bottle, Puji Faitna, Paul Aylin, Martin R Cowie

Open access · goldAbstract read
In one paragraph

Article in ESC heart failure, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Long-term outcomes of pace-and-ablate strategy in patients with atrial fibrillation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2025
    Article
  4. Article
  5. A Closer Look-Who Are We Screening for Lung Cancer?Mayo Clinic proceedings. Innovations, quality & outcomes · 2023
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Alex BottleDr Foster Unit, School of Public Health, Faculty of Medicine, Imperial College London, London, UK.
Puji FaitnaDr Foster Unit, School of Public Health, Faculty of Medicine, Imperial College London, London, UK.ORCID 0000-0003-3982-9089
Paul AylinDr Foster Unit, School of Public Health, Faculty of Medicine, Imperial College London, London, UK.
Martin R CowieNational Heart and Lung Institute, Faculty of Medicine, Imperial College London, Dovehouse Street, London, SW3 6LY, UK.ORCID 0000-0001-7457-2552
Imperial College London · GBLung Institute · US

Funding

Department of Health
6 · The paper itself

Abstract

aimsGuidelines recommend the use of an implantable cardioverter-defibrillator (ICD) and/or cardiac resynchronization therapy (CRT) device based on the results of randomized controlled trials (RCTs), typically with selected patients and short follow-up. METHODS AND

resultsWe describe the 5 year survival rate and use of hospital services following ICD and CRT implantation in England from April 2011 to March 2013 using the national hospital administrative database covering emergency department visits, inpatient admissions, and clinic appointments, linked to the national death register. Five-year survival was 64% after ICD implantation and 58% after CRT implantation, with median survival times of 6.8 and 6.2 years, respectively. Hospital use was high in both device groups, for the 5 years prior and after implantation, peaking around the implantation date. Most hospital activity was not primarily related to heart failure. Healthcare costs were dominated by admissions, but emergency department and clinic activity were both high. Only the CRT group saw total per-patient costs fall after the index month (implantation), driven by a slight fall in the heart failure admission rate. Patients were typically older than in the trials, but with similar co-morbidity except for substantially more atrial fibrillation and less dementia. Survival and device complications were similar to the RCTs.

conclusionsClinical and cost-effectiveness assessments of ICD and CRT implantation are supported by real-world data, although the prevalence of atrial fibrillation remains substantially higher than in the RCTs.

Indexed as

Atrial FibrillationCardiac Resynchronization TherapyDefibrillators, ImplantableHeart FailureHospitalsHumansAdministrative dataCardiac implantable electronic devicesCardiac resynchronization therapy (CRT)Heart failureImplantable cardioverter-defibrillator (ICD)Real-world data

Identifiers

PMID33932129
PMCPMC8318487
OpenAlexW3159116444

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.