Evidence map›Paper›PMID 33931680›Full record

ArticleScientific reports2021

Variability in stem taper surface topography affects the degree of corrosion and fretting in total hip arthroplasty.

Kilian Elia Stockhausen, Christoph Riedel, Alex Victoria Belinski, Dorothea Rothe, Thorsten Gehrke, Felix Klebig, Matthias Gebauer, Michael Amling, Mustafa Citak, Björn Busse

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Kilian Elia Stockhausen *Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany.
Christoph Riedel *Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany.
Alex Victoria BelinskiDepartment of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany.
Dorothea RotheDepartment of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany.
Thorsten GehrkeDepartment of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany.
Felix KlebigDepartment of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany.
Matthias GebauerDepartment of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany.
Michael AmlingDepartment of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany.
Mustafa CitakDepartment of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany.
Björn BusseDepartment of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany. b.busse@uke.uni-hamburg.de.
Helios Endo-Klinik Hamburg · DEUniversity Medical Center Hamburg-Eppendorf · DESupply Chain Competence Center (Germany) · DEUniversität Hamburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Degradation at the modular head-neck interface in total hip arthroplasty (THA) is predominately expressed in the form of corrosion and fretting, potentially causing peri-prosthetic failure by adverse reactions to metal debris. This retrieval study aimed to quantify variations in stem taper surface topographies and to assess the influence on the formation of corrosion and/or fretting in titanium alloy stem tapers combined with metal and ceramic heads. Four hip stem designs (Alloclassic, CLS, Bicontact and SL-Plus) were characterized using high-resolution 3D microscopy, and corrosion and fretting were rated using the Goldberg scoring scheme. Quantification of the taper surface topographies revealed a high variability in surface characteristics between threaded stem tapers: Alloclassic and CLS tapers feature deeply threaded trapezoid-shaped profiles with thread heights over 65 µm. The sawtooth-shaped Bicontact and triangular SL-Plus taper are characterized by low thread heights below 14 µm. Significantly lower corrosion and fretting scores were observed in lightly threaded compared to deeply threaded tapers in ceramic head combinations. No significant differences in corrosion or fretting scores with thread height were found in pairings with metal heads. Understanding the relationship between stem taper surface topography and the formation of corrosion and fretting could help to improve the performance of modern THAs and lead to longer-lasting clinical results.

Indexed as

Stress, MechanicalAgedArthroplasty, Replacement, HipCeramicsChromium AlloysCorrosionFemaleHip JointHip ProsthesisHumansMaleMiddle AgedProsthesis DesignProsthesis FailureRetrospective StudiesRisk FactorsChromium Alloys

Identifiers

PMID33931680
PMCPMC8087796
OpenAlexW3159129401

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.