Accuracy assessment methods for physiological model selection toward evaluation of closed-loop controlled medical devices.

Ramin Bighamian, Jin-Oh Hahn, George Kramer, Christopher Scully

Abstract readEvaluation Study
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ramin BighamianOffice of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, United States of America.ORCID 0000-0002-2660-0851
Jin-Oh HahnDepartment of Mechanical Engineering, University of Maryland, College Park, MD, United States of America.
George KramerDepartment of Anesthesiology, The University of Texas Medical Branch, Galveston, TX, United States of America.
Christopher ScullyOffice of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Physiological closed-loop controlled (PCLC) medical devices are complex systems integrating one or more medical devices with a patient's physiology through closed-loop control algorithms; introducing many failure modes and parameters that impact performance. These control algorithms should be tested through safety and efficacy trials to compare their performance to the standard of care and determine whether there is sufficient evidence of safety for their use in real care setting. With this aim, credible mathematical models have been constructed and used throughout the development and evaluation phases of a PCLC medical device to support the engineering design and improve safety aspects. Uncertainties about the fidelity of these models and ambiguities about the choice of measures for modeling performance need to be addressed before a reliable PCLC evaluation can be achieved. This research develops tools for evaluating the accuracy of physiological models and establishes fundamental measures for predictive capability assessment across different physiological models. As a case study, we built a refined physiological model of blood volume (BV) response by expanding an original model we developed in our prior work. Using experimental data collected from 16 sheep undergoing hemorrhage and fluid resuscitation, first, we compared the calibration performance of the two candidate physiological models, i.e., original and refined, using root-mean-squared error (RMSE), Akiake information criterion (AIC), and a new multi-dimensional approach utilizing normalized features extracted from the fitting error. Compared to the original model, the refined model demonstrated a significant improvement in calibration performance in terms of RMSE (9%, P = 0.03) and multi-dimensional measure (48%, P = 0.02), while a comparable AIC between the two models verified that the enhanced calibration performance in the refined model is not due to data over-fitting. Second, we compared the physiological predictive capability of the two models under three different scenarios: prediction of subject-specific steady-state BV response, subject-specific transient BV response to hemorrhage perturbation, and leave-one-out inter-subject BV response. Results indicated enhanced accuracy and predictive capability for the refined physiological model with significantly larger proportion of measurements that were within the prediction envelope in the transient and leave-one-out prediction scenarios (P < 0.02). All together, this study helps to identify and merge new methods for credibility assessment and physiological model selection, leading to a more efficient process for PCLC medical device evaluation.

Indexed as

AlgorithmsAnimalsBlood VolumeDecision Support Systems, ClinicalEquipment and SuppliesFluid TherapyHemorrhageModels, TheoreticalResuscitationSheepTechnology Assessment, Biomedical

Identifiers

PMID33930095
PMCPMC8087034

What OpenQuestion holds

Textmetadata
LicenceCC0
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.