In one paragraph

Article in Indian journal of orthopaedics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Dong Won SuhJoint Center, Barunsesang Hospital, #5, Yatap-ro 75beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13497 South Korea.
Woo Jin YeoJoint Center, Barunsesang Hospital, #5, Yatap-ro 75beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13497 South Korea.
Seung Beom HanDepartment of Orthopedic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea.
Sang-Yeon SoJoint Center, Barunsesang Hospital, #5, Yatap-ro 75beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13497 South Korea.
Bong Soo KyungJoint Center, Barunsesang Hospital, #5, Yatap-ro 75beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13497 South Korea.ORCID 0000-0002-4442-8872
Bundang Jesaeng Hospital · KRKorea University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the radiological and clinical outcomes using simple medial meniscus posterior horn (MMPH) root repair using an all-inside meniscal repair device combined with high tibial osteotomy (HTO) and HTO alone.

methodsBetween November 2013 and December 2016, patients treated for MMPH root tear along with HTO were enrolled. Based on the tear gap, the participants were divided into repairable (< 2 mm) and unrepairable (> 2 mm) categories. The participants in each group were divided into those amenable to simple MMPH root repair using an all-inside meniscal repair device and those that required no procedure for meniscus. Radiological parameters including mechanical femorotibial alignment (MA), posterior tibial slope (PTS) and medial joint-space width (JSW) were evaluated preoperatively and postoperatively at 2 years. For clinical evaluation, the WOMAC score was determined at the 2-year visit postoperatively.

resultsA total of 81 knees including 48 repairable (group R) and 33 unrepairable (group I) knees were enrolled. A total of 43 knees underwent simple MMPH root repair using an all-inside meniscal repair device (subgroup

conclusionSimple MMPH root repair using an all-inside meniscal repair device combined with HTO was more effective for the maintenance of JSW compared with HTO without a meniscal procedure in patients with repairable MMPH root tear and varus alignment. However, other options are needed for unrepairable MMPH root tear.

Indexed as

Joint-space widthKneeMedial meniscus posterior hornMedial meniscus posterior horn root tearOsteotomySimple all inside meniscal repair device repair

Identifiers

PMID33927818
PMCPMC8046862
OpenAlexW3082298253

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.