Evidence map›Paper›PMID 33924812›Full record

ArticleSensors (Basel, Switzerland)2021

Characterization of Inkjet-Printed Digital Microfluidics Devices.

Shiyu Chen, Zhidong He, Suhwan Choi, Igor V Novosselov

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shiyu ChenDepartment of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA.
Zhidong HeDepartment of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA.
Suhwan ChoiDepartment of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA.
Igor V NovosselovDepartment of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA.ORCID 0000-0002-6347-7450

Funding

Development of the Total Exposure Monitoring Unit (TEMU) for Pediatric AsthmaU01EB021923 · NIBIB · UNIVERSITY OF WASHINGTON · PI SETO, EDMUND · 2015 to 2018
$1.9M
Aerosol Sampling and Microfluidic Analysis of Reactive Oxygen SpeciesR42ES026532 · NIEHS · ILLIONIX, LLC · PI ZYUZIN, ALEXEI · 2016 to 2018
$1.4M
NIBIB NIH HHS U01 EB021923NIEHS NIH HHS R42ES026532
6 · The paper itself

Abstract

Digital microfluidics (DMF) devices enable precise manipulation of small liquid volumes in point-of-care testing. A printed circuit board (PCB) substrate is commonly utilized to build DMF devices. However, inkjet printing can be used to fabricate DMF circuits, providing a less expensive alternative to PCB-based DMF designs while enabling more rapid design iteration cycles. We demonstrate the cleanroom-free fabrication process of a low-cost inkjet-printed DMF circuit. We compare Kapton and polymethyl methacrylate (PMMA) as dielectric coatings by measuring the minimal droplet actuation voltage for a range of actuation frequencies. A minimum actuation voltage of 5.6 V was required for droplet movement with the PMMA layer thickness of 0.2 μm and a hydrophobic layer of 0.17 μm. Significant issues with PMMA dielectric breakdown were observed at actuation voltages above 10 V. In comparison, devices that utilized Kapton were found to be more robust, even at an actuation voltage up to 100 V.

Indexed as

Lab-On-A-Chip DevicesMicrofluidicsAg inkdigital microfluidicsinkjet printingKaptonPMMA

Identifiers

PMID33924812
PMCPMC8125221

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.