Evidence map›Paper›PMID 33923587›Full record

ArticleSensors (Basel, Switzerland)2021

Estimation of the Continuous Walking Angle of Knee and Ankle (Talocrural Joint, Subtalar Joint) of a Lower-Limb Exoskeleton Robot Using a Neural Network.

Taehoon Lee, Inwoo Kim, Soo-Hong Lee

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Review on Portable-Powered Lower Limb Exoskeletons.Sensors (Basel, Switzerland) · 2024
    Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Taehoon LeeDepartment of Mechanical Engineering, Yonsei University, Seoul 03722, Korea.
Inwoo KimDepartment of Mechanical Engineering, Yonsei University, Seoul 03722, Korea.ORCID 0000-0002-9453-7698
Soo-Hong LeeDepartment of Mechanical Engineering, Yonsei University, Seoul 03722, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A lower-limb exoskeleton robot identifies the wearer's walking intention and assists the walking movement through mechanical force; thus, it is important to be able to identify the wearer's movement in real-time. Measurement of the angle of the knee and ankle can be difficult in the case of patients who cannot move the lower-limb joint properly. Therefore, in this study, the knee angle as well as the angles of the talocrural and subtalar joints of the ankle were estimated during walking by applying the neural network to two inertial measurement unit (IMU) sensors attached to the thigh and shank. First, for angle estimation, the gyroscope and accelerometer data of the IMU sensor were obtained while walking at a treadmill speed of 1 to 2.5 km/h while wearing an exoskeleton robot. The weights according to each walking speed were calculated using a neural network algorithm programmed in MATLAB software. Second, an appropriate weight was selected according to the walking speed through the IMU data, and the knee angle and the angles of the talocrural and subtalar joints of the ankle were estimated in real-time during walking through a feedforward neural network using the IMU data received in real-time. We confirmed that the angle estimation error was accurately estimated as 1.69° ± 1.43 (mean absolute error (MAE) ± standard deviation (SD)) for the knee joint, 1.29° ± 1.01 for the talocrural joint, and 0.82° ± 0.69 for the subtalar joint. Therefore, the proposed algorithm has potential for gait rehabilitation as it addresses the difficulty of estimating angles of lower extremity patients using torque and EMG sensors.

Indexed as

Exoskeleton DeviceRoboticsSubtalar JointAnkleAnkle JointBiomechanical PhenomenaGaitHumansKnee JointLower ExtremityNeural Networks, ComputerWalkingartificial neural networkknee and ankle angle estimationlower-limb exoskeletonreal-time motion profileswalking pattern

Identifiers

PMID33923587
PMCPMC8072591

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.