Evidence map›Paper›PMID 33921468›Full record

ArticleSensors (Basel, Switzerland)2021

Nonlinear T-Wave Time Warping-Based Sensing Model for Non-Invasive Personalised Blood Potassium Monitoring in Hemodialysis Patients: A Pilot Study.

Flavio Palmieri, Pedro Gomis, José Esteban Ruiz, Dina Ferreira, Alba Martín-Yebra, Esther Pueyo, Juan Pablo Martínez, Julia Ramírez, Pablo Laguna

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Flavio PalmieriCentre de Recerca en Enginyeria Biomèdica, Universitat Politècnica de Catalunya, 08028 Barcelona, Spain.ORCID 0000-0002-1455-4923
Pedro GomisCentre de Recerca en Enginyeria Biomèdica, Universitat Politècnica de Catalunya, 08028 Barcelona, Spain.ORCID 0000-0002-2058-7115
José Esteban RuizNephrology Ward, Hospital Clínico Universitario Lozano Blesa, 50009 Zaragoza, Spain.
Dina FerreiraLaboratorios Rubió, Castellbisbal, 08755 Barcelona, Spain.
Alba Martín-YebraCIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza, Spain.ORCID 0000-0003-0226-4950
Esther PueyoCIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza, Spain.ORCID 0000-0002-1960-407X
Juan Pablo MartínezCIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza, Spain.ORCID 0000-0002-7503-3339
Julia RamírezWilliam Harvey Research Institute, Queen Mary University of London, London E1 4NS, UK.ORCID 0000-0003-4130-5866
Pablo LagunaCIBER en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 50018 Zaragoza, Spain.ORCID 0000-0003-3434-9254
Universidad de Zaragoza · ESBiomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine · ESHospital Clínico Universitario Lozano Blesa · ESQueen Mary University of London · GBValencian International University · ES

Funding

Agència de Gestió d'Ajuts Universitaris i de Recerca DI001-2018CIBER-BBN DEKOALEEuropean Research Council ERC-StG-638284Gobierno de Aragón LMP124-18 & T39-20RJuan de la Cierva FJC2018-037369-IMarie Sklodowska-Curie 786833Ministerio de Ciencia e Innovación PID2019-105674RB-I00Products & Technology S.L. DI001-2018
6 · The paper itself

Abstract

backgroundEnd-stage renal disease patients undergoing hemodialysis (ESRD-HD) therapy are highly susceptible to malignant ventricular arrhythmias caused by undetected potassium concentration ([K+]) variations (Δ[K+]) out of normal ranges. Therefore, a reliable method for continuous, noninvasive monitoring of [K+] is crucial. The morphology of the T-wave in the electrocardiogram (ECG) reflects Δ[K+] and two time-warping-based T-wave morphological parameters, dw and its heart-rate corrected version dw,c, have been shown to reliably track Δ[K+] from the ECG. The aim of this study is to derive polynomial models relating dw and dw,c with Δ[K+], and to test their ability to reliably sense and quantify Δ[K+] values.

methods48-hour Holter ECGs and [K+] values from six blood samples were collected from 29 ESRD-HD patients. For every patient, dw and dw,c were computed, and linear, quadratic, and cubic fitting models were derived from them. Then, Spearman's (ρ) and Pearson's ( RESULTS AND DISCUSSIONS: Nonlinear models were the most suitable for Δ[K+] estimation, rendering higher Pearson's correlation (median 0.77 ≤r≤ 0.92) and smaller estimation error (median 0.20 ≤ed≤ 0.43) than the linear model (median 0.76 ≤r≤ 0.86 and 0.30 ≤ed≤ 0.40), even if similar Spearman's ρ were found across models (median 0.77 ≤ρ≤ 0.83).

conclusionResults support the use of nonlinear T-wave-based models as Δ[K+] sensors in ESRD-HD patients.

Indexed as

Nonlinear DynamicsRenal DialysisArrhythmias, CardiacElectrocardiographyHumansPilot ProjectsPotassiumPotassiumelectrocardiogramnoninvasive potassium sensingperiodic component analysispersonalised medicinetime warpingT-wave morphology

Identifiers

PMID33921468
PMCPMC8069025
OpenAlexW3152893241

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.