ArticleJournal of clinical medicine2021
Association of Guideline-Based Medical Therapy with Malignant Arrhythmias and Mortality among Heart Failure Patients Implanted with Cardioverter Defibrillator (ICD) or Cardiac Resynchronization-Defibrillator Device (CRTD).
Article in Journal of clinical medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimEvaluate prevalence of heart failure (HF) medications and their association with ventricular arrhythmia (VA) and survival among patients implanted with primary prevention implantable cardiac defibrillator (ICD)/cardiac resynchronization therapy + defibrillator (CRTD) devices.
methodsAssociation of treatment and dose (% guideline recommended target) of beta-adrenergic receptor antagonist (BB), angiotensin-antagonists (AngA), and mineralocorticoid-antagonists (MRA), after ICD/CRTD implant with VA and mortality was retrospectively analyzed.
resultsStudy included 186 HF patients; 42.5% and 57.5% implanted with ICD and CRTD, respectively. During 3.8 (2.1;6.7) years; 52 (28%) had VA and 77 (41.4%) died. Treatment (% of patients) included: BB (83%), AngA (87%), and MRA (59%). Median doses were 25(12.5;50)% of target for all medications. BB treatment >25% target dose was associated with reduced VA incidence. In the multivariable model including age, gender, diabetes, heart rate, and medication doses, increased BB dose was associated with reduced VA (hazard ratio (HR) 0.443 95% CI 0.222-0.885;
conclusionsIn this cohort of real-life HF patients discharged after ICD/CRTD implant, prevalence of guideline-based HF medications was high, albeit with low doses. Higher BB dose was associated with reduced VA, while AngA was associated with improved survival.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.