Evidence map›Paper›PMID 33920553›Full record

ReviewJournal of clinical medicine2021

Cardiac Implantable Electronic Devices in Hemodialysis and Chronic Kidney Disease Patients-An Experience-Based Narrative Review.

Krzysztof Nowak, Mariusz Kusztal

Open access · goldAbstract readReview
In one paragraph

Review in Journal of clinical medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Krzysztof NowakDepartment of Heart Diseases, Wroclaw Medical University, 50-556 Wroclaw, Poland.ORCID 0000-0001-9078-0087
Mariusz KusztalDepartment of Nephrology and Transplantation Medicine, Wroclaw Medical University, 50-556 Wroclaw, Poland.ORCID 0000-0002-6502-0374
Wroclaw Medical University · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiovascular implantable electronic devices (CIEDs) are a standard therapy utilized for different cardiac conditions. They are implanted in a growing number of patients, including those with chronic kidney disease (CKD) and end-stage kidney disease (ESKD). Cardiovascular diseases, including heart failure and malignant arrhythmia, remain the leading cause of mortality among CKD patients, especially in ESKD. CIED implantation procedures are considered minor surgery, typically with transvenous leads inserted via upper central veins, followed by an impulse generator introduced subcutaneously. A decision regarding optimal hemodialysis (HD) modality and the choice of permanent vascular access (VA) could be particularly challenging in CIED recipients. The potential consequences of arteriovenous access on the CIED side are related to (1) venous hypertension from lead-related central vein stenosis and (2) the risk of systemic infection. Therefore, when creating permanent vascular access, the clinical scenario may be complicated by the CIED presence on one side and the lack of suitable vessels for arteriovenous fistula on the contralateral arm. These factors suggest the need for an individualized approach according to different clinical situations: (1) CIED in a CKD patient; (2) CIED in a patient on hemodialysis CIED; and (3) VA in a patient with CIED. This complex clinical conundrum creates the necessity for close cooperation between cardiologists and nephrologists.

Indexed as

cardiovascular implantable electronic devicechronic kidney diseasehemodialysisvein stenosis

Identifiers

PMID33920553
PMCPMC8073061
OpenAlexW3153124987

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.