Evidence map›Paper›PMID 33920183›Full record

ArticleSensors (Basel, Switzerland)2021

Electrochemical DNA Biosensor That Detects Early Celiac Disease Autoantibodies.

Anna B N Nguyen, Marcos Maldonado, Dylan Poch, Tyler Sodia, Andrew Smith, Teisha J Rowland, Andrew J Bonham

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Anna B N NguyenBiomolecular Sciences and Engineering Program, University of California, Santa Barbara, Santa Barbara, CA 93106, USA.
Marcos MaldonadoDepartment of Chemistry & Biochemistry, Metropolitan State University of Denver, Denver, CO 80204, USA.
Dylan PochDepartment of Chemistry & Biochemistry, Metropolitan State University of Denver, Denver, CO 80204, USA.ORCID 0000-0001-9088-4281
Tyler SodiaDepartment of Chemistry & Biochemistry, Metropolitan State University of Denver, Denver, CO 80204, USA.
Andrew SmithDepartment of Chemistry & Biochemistry, Metropolitan State University of Denver, Denver, CO 80204, USA.ORCID 0000-0002-0016-3489
Teisha J RowlandDepartment of Molecular, Cellular, and Developmental Biology, University of Colorado, Boulder, CO 80309, USA.
Andrew J BonhamDepartment of Chemistry & Biochemistry, Metropolitan State University of Denver, Denver, CO 80204, USA.ORCID 0000-0003-1591-8378
Metropolitan State University of Denver · USUniversity of California, Santa Barbara · USUniversity of Colorado Boulder · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Although it is estimated that more than one million Americans have celiac disease (CD), it remains challenging to diagnose. CD, an autoimmune and inflammatory response following the ingestion of gluten-containing foods, has symptoms overlapping with other diseases and requires invasive diagnostics. The gold standard for CD diagnosis involves serologic blood tests followed by invasive confirmatory biopsies. Here, we propose a less invasive method using an electrochemical DNA (E-DNA) biosensor for CD-specific autoantibodies (AABs) circulating in blood. In our approach, CD-specific AABs bind a synthetic neoepitope, causing a conformational change in the biosensor, as well as a change in the environment of an attached redox reporter, producing a measurable current reduction. We assessed the biosensor's ability to detect CD-specific patient-derived AABs in physiological buffer as well as buffer supplemented with bovine serum. Our biosensor was able to detect AABs in a dose-dependent manner; increased signal change correlated with increased AAB concentration with an apparent dissociation constant of 0.09 ± 0.03 units/mL of AABs. Furthermore, we found our biosensor to be target-specific, with minimal off-target binding of multiple unrelated biomarkers. Future efforts aimed at increasing sensitivity in complex media may build upon the biosensor design presented here to further improve CD AAB detection and CD diagnostic tools.

Indexed as

Biosensing TechniquesCeliac DiseaseAnimalsAutoantibodiesBiomarkersCattleDNAHumansAutoantibodiesBiomarkersDNAbiosensorceliac diseaseceliac disease autoantibodiesceliac disease autoantibody epitopeceliac disease diagnosticsE-DNA-based biosensors

Identifiers

PMID33920183
PMCPMC8070315
OpenAlexW3154878039

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.