Evidence map›Paper›PMID 33920125›Full record

ArticleSensors (Basel, Switzerland)2021

Towards Tracking of Deep Brain Stimulation Electrodes Using an Integrated Magnetometer.

Thomas Quirin, Corentin Féry, Dorian Vogel, Céline Vergne, Mathieu Sarracanie, Najat Salameh, Morgan Madec, Simone Hemm, Luc Hébrard, Joris Pascal

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Thomas QuirinInstitute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), 4132 Muttenz, Switzerland.ORCID 0000-0003-4919-278X
Corentin FéryInstitute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), 4132 Muttenz, Switzerland.ORCID 0000-0002-6599-4988
Dorian VogelInstitute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), 4132 Muttenz, Switzerland.ORCID 0000-0003-3445-576X
Céline VergneInstitute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), 4132 Muttenz, Switzerland.
Mathieu SarracanieCenter for Adaptable MRI Technology, Department of Biomedical Engineering, University of Basel, 4123 Allschwil, Switzerland.
Najat SalamehCenter for Adaptable MRI Technology, Department of Biomedical Engineering, University of Basel, 4123 Allschwil, Switzerland.
Morgan MadecIcube laboratory, UMR 7357 (University of Strasbourg/CNRS), 67412 Illkirch, France.ORCID 0000-0001-9537-642X
Simone HemmInstitute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), 4132 Muttenz, Switzerland.
Luc HébrardIcube laboratory, UMR 7357 (University of Strasbourg/CNRS), 67412 Illkirch, France.
Joris PascalInstitute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), 4132 Muttenz, Switzerland.ORCID 0000-0001-6049-3271

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a tracking system using magnetometers, possibly integrable in a deep brain stimulation (DBS) electrode. DBS is a treatment for movement disorders where the position of the implant is of prime importance. Positioning challenges during the surgery could be addressed thanks to a magnetic tracking. The system proposed in this paper, complementary to existing procedures, has been designed to bridge preoperative clinical imaging with DBS surgery, allowing the surgeon to increase his/her control on the implantation trajectory. Here the magnetic source required for tracking consists of three coils, and is experimentally mapped. This mapping has been performed with an in-house three-dimensional magnetic camera. The system demonstrates how magnetometers integrated directly at the tip of a DBS electrode, might improve treatment by monitoring the position during and after the surgery. The three-dimensional operation without line of sight has been demonstrated using a reference obtained with magnetic resonance imaging (MRI) of a simplified brain model. We observed experimentally a mean absolute error of 1.35 mm and an Euclidean error of 3.07 mm. Several areas of improvement to target errors below 1 mm are also discussed.

Indexed as

Deep Brain StimulationElectrodes, ImplantedHumansMagnetic Resonance Imagingdeep brain stimulationimage guided interventionmagnetic field mappingmagnetic tracking systemthree-dimensional magnetometer

Identifiers

PMID33920125
PMCPMC8068940

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.