ArticleSensors (Basel, Switzerland)2021
A Simple Method for Compensating Harmonic Distortion in Current Transformers: Experimental Validation.
Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Modeling of Measuring Transducers for Relay Protection Systems of Electrical Installations.Sensors (Basel, Switzerland) · 2025Article
- Development of Inductive Current Transformer 400/5/1 of Class 0.2S for Frequency Range 50 Hz-5 kHz.Sensors (Basel, Switzerland) · 2024Article
- Non-Parametric Statistical Analysis of Current Waveforms through Power System Sensors.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Conventional current transformers (CTs) suffer from nonlinearities due to their ferromagnetic cores. On one hand, it is well-known that severe core saturation may occur because of large overcurrents or unidirectional transient components: this may substantially impact the operation of relays. On the other hand, weaker nonlinear effects are also present during regular working conditions. In particular, the spectral content of typical current waveforms is characterized by a strong fundamental term responsible for harmonic distortion affecting the frequency components at the secondary side. In turn, this has a significant impact on the accuracy that can be reached as long as current harmonics must be monitored. The target of this work is implementing a simple signal processing technique that allows compensating for this effect. The method, characterized by extremely low computational complexity, is first introduced and validated using numerical simulations. After this, it was tested experimentally to improve the harmonic measurement capability of inductive CTs. The achieved results highlight a noticeable reduction of errors at low-order harmonics over a wide range of primary current amplitudes. It is worth noting that the black-box approach makes the technique suitable also for compensating nonlinearities introduced by current transducers based on different operating principles. Thanks to this peculiarity and to the low computational complexity, the proposed method is suitable to be employed in power quality analyzers and merging units. In this way, high-accuracy monitoring of current harmonics in power systems can be achieved, opening the way to advanced power quality management and to the location of disturbing users.