Evidence map›Paper›PMID 33918647›Full record

ArticleJournal of functional biomaterials2021

Personalized Biomechanical Analysis of the Mandible Teeth Behavior in the Treatment of Masticatory Muscles Parafunction.

Denis Gribov, Mikhail Antonik, Denis Butkov, Alexandr Stepanov, Pavel Antonik, Yaser Kharakh, Anton Pivovarov, Sergey Arutyunov

Registry-linked trialAbstract read
In one paragraph

Article in Journal of functional biomaterials, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05007691 (Single-group, Comparative Biomechanical Study of Maxillary and Mandibular Splints Used for the Treatment of Masticatory Muscle Parafunction), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05007691 naunknown statusnot on this map

Single-group, Comparative Biomechanical Study of Maxillary and Mandibular Splints Used for the Treatment of Masticatory Muscle Parafunction

TypeinterventionalSponsorMoscow State University of Medicine and DentistryRan2021 to 2022Enrolled12ConditionsJaw, Edentulous, Mouth, EdentulousArmsOcclusal splint
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Denis GribovDepartment of Applied Mechanics, Bauman Moscow State Technical University, 105005 Moscow, Russia.
Mikhail AntonikDepartment of Propaedeutics of Dental Diseases, A.I. Yevdokimov Moscow State University of Medicine and Dentistry, 127473 Moscow, Russia.
Denis ButkovDepartment of Propaedeutics of Dental Diseases, A.I. Yevdokimov Moscow State University of Medicine and Dentistry, 127473 Moscow, Russia.
Alexandr StepanovDepartment of Propaedeutics of Dental Diseases, A.I. Yevdokimov Moscow State University of Medicine and Dentistry, 127473 Moscow, Russia.
Pavel AntonikDepartment of Propaedeutics of Dental Diseases, A.I. Yevdokimov Moscow State University of Medicine and Dentistry, 127473 Moscow, Russia.
Yaser KharakhDepartment of Propaedeutics of Dental Diseases, A.I. Yevdokimov Moscow State University of Medicine and Dentistry, 127473 Moscow, Russia.
Anton PivovarovDepartment of Propaedeutics of Dental Diseases, A.I. Yevdokimov Moscow State University of Medicine and Dentistry, 127473 Moscow, Russia.
Sergey ArutyunovDepartment of Propaedeutics of Dental Diseases, A.I. Yevdokimov Moscow State University of Medicine and Dentistry, 127473 Moscow, Russia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A 3D finite element model of the mandible dentition was developed, including 14 teeth, a periodontal ligament (PDL), and a splint made of polymethylmethacrylate (PMMA). The study considered three design options: 1-the case of splint absence; 2-the case of the splint presence installed after manufacture; and 3-the case of splint presence installed after correction (grinding) performed to ensure a uniform distribution of occlusal force between the teeth. For cases of absence and presence of splint, three measurements of the functional load were performed using the T-Scan III software and hardware complex (TekScan, Boston, MA, USA). It was found that the presence of a splint led to a decrease in the total value of the occlusive load and to a uniform distribution between all the mandible teeth. The occlusal force was considered as a static vertical force evenly distributed between the nodes belonging to the occlusive surface of the corresponding tooth for the first design option and the occlusal surface of the splint for the second and third ones, respectively. As a result of the study, it was concluded that the splint usage was effective in order to change the distribution of the functional load during the treatment of proved masticatory muscles' parafunction; the safety of using a splint for teeth and surrounding tissues under the influence of the considered functional load was shown; the potential applicability of PMMA as a structural material of a splint that had been used for the treatment of masticatory muscles' parafunction was established.

Indexed as

balancedbruxismcase reportsdentaldental occlusiondental stress analysisfinite element analysisocclusal splintspolymethyl methacrylateprintingthree-dimensional technology

Identifiers

PMID33918647
PMCPMC8167636