Evidence map›Paper›PMID 33918524›Full record

ArticleBiosensors2021

Highly Sensitive Twin Resonance Coupling Refractive Index Sensor Based on Gold- and MgF

Kawsar Ahmed, Mohammed A AlZain, Hasan Abdullah, Yanhua Luo, Dhasarathan Vigneswaran, Osama S Faragallah, Mahmoud M A Eid, Ahmed Nabih Zaki Rashed

Abstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kawsar AhmedGroup of Biophotomatiχ, Department of ICT, MBSTU, Tangail 1902, Bangladesh.ORCID 0000-0002-4034-9819
Mohammed A AlZainDepartment of Information Technology, College of Computers and Information Technology, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.ORCID 0000-0001-5595-4280
Hasan AbdullahGroup of Biophotomatiχ, Department of ICT, MBSTU, Tangail 1902, Bangladesh.
Yanhua LuoPhotonics & Optical Communication, School of Electrical Engineering & Telecommunications, University of New South Wales, Sydney, NSW 2052, Australia.ORCID 0000-0002-5929-6083
Dhasarathan VigneswaranDepartment of Electronics and Communication, Sri Krishna College of Technology, Coimbatore 641 042, India.
Osama S FaragallahDepartment of Information Technology, College of Computers and Information Technology, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.ORCID 0000-0003-1982-335X
Mahmoud M A EidDepartment of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.ORCID 0000-0002-0423-7983
Ahmed Nabih Zaki RashedDepartment of EECE, Faculty of Electronic Engineering, Menoufia University, Menouf 32951, Egypt.

Funding

Deanship of Scientific Research, Taif University, Taif, Saudi Arabia TURSP-2020/08
6 · The paper itself

Abstract

A plasmonic material-coated circular-shaped photonic crystal fiber (C-PCF) sensor based on surface plasmon resonance (SPR) is proposed to explore the optical guiding performance of the refractive index (RI) sensing at 1.7-3.7 μm. A twin resonance coupling profile is observed by selectively infiltrating liquid using finite element method (FEM). A nano-ring gold layer with a magnesium fluoride (MgF2) coating and fused silica are used as plasmonic and base material, respectively, that help to achieve maximum sensing performance. RI analytes are highly sensitive to SPR and are injected into the outmost air holes of the cladding. The highest sensitivity of 27,958.49 nm/RIU, birefringence of 3.9 × 10-4, resolution of 3.70094 × 10-5 RIU, and transmittance dip of -34 dB are achieved. The proposed work is a purely numerical simulation with proper optimization. The value of optimization has been referred to with an experimental tolerance value, but at the same time it has been ensured that it is not fabricated and tested. In summary, the explored C-PCF can widely be eligible for RI-based sensing applications for its excellent performance, which makes it a solid candidate for next generation biosensing applications.

Indexed as

Biosensing TechniquesRefractometryComputer SimulationFluoridesGoldMagnesium CompoundsNanostructuresPhotonsSilverSurface Plasmon ResonanceFluoridesGoldMagnesium Compoundsmagnesium fluorideSilverbirefringencePCFrefractive index sensorsensitivitysurface plasmon resonance

Identifiers

PMID33918524
PMCPMC8066326

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.